Discharge current
DSCH CURRENT
Set the desired discharge current (0.1 ... 8.0 A) here. This setting depends on the rechargeable
battery at hand.
Please note that the charger's discharging capacity does not exceed 30 W. For this
reason, the charger can not supply the maximum discharge current in the case of
rechargeable batteries with many cells.
End discharge voltage per cell
DSCH VOLTAGE
3.0V/CELL
Here, set the voltage per cell that will stop discharging when reached.
Caution!
Never set too low a voltage. In the case of lithium rechargeable batteries, this may
result in deep discharge or permanent damage to the battery!
End charging voltage per cell
TVC=YOUR RISK!
In the case of lithium rechargeable batteries, set the voltage per cell that will stop charging
when reached here.
Caution!
Never set too high a voltage. In the case of lithium rechargeable batteries, this may
result in a fire or the rechargeable battery exploding!
1.2A
4.20V
107