PLAYBACK PHASE ADJUSTMENT
TEST POINTS
MEASURING EQUIPMENT
ADJUSTMENT
TESTPUNKTE
MESSGERÄTE
EINSTELLUNG
The Phase generator (PG) shifter decides the VIDEO
HEAD switching point when a TAPE is played back. In
case the Phase generator (PG) shifter is not correctly
tuned, HEAD switching noise or vertical jitter may occur.
1) Connect the PATH ADJ. JIG to PTO1 of the MAIN
CIRCUIT BOARD.
2) Play the ALIGNMENT TAPE (COLOUR BAR SIGNAL
OR MONOSCOPE SIGNAL).
3) Connect the channel-1 scope probe to the S/W PULSE
TEST PIN of the PATH ADJ. JIG.
4) Connect the channel-2 scope probe (1V/div.) to the
VIDEO OUT of the MAIN CIRCUIT BOARD.
5) Play back the ALIGNMENT TAPE.
6) Adjust the PG volume for time interval of 6,5Hz±0,5Hz
between switching pulse and V-sync signal.
SW PULSE
SCHALT-IMPULS
VIDEO OUTPUT
VIDEOAUSGABE
Downloaded from
www.Manualslib.com
SCHALT-IMPULS-TESTPIN
VR595 (PG-VERSCHIEBER)
SWITCHING
SCHALTEN
Playback phase adjustment
Playback-phaseneinstellung
manuals search engine
PLAYBACK-PHASENEINSTELLUNG
S/W PULSE TEST PIN
VIDEO OUT
OSCILLOSCOPE
VR595 (PG SHIFTER)
VIDEO AUSGABE
OSZILLOSKOP
Der Phasengenerator-Verschieber entscheidet, wo der
Schaltpunkt des VIDEO HEAD liegt, wenn ein Band
abgespielt wird. Ist der Phasengenerator (PG) nicht richtig
abgestimmt, können HEAD-Schaltgeräusche oder
vertikaler Jitter auftreten.
1) Schließen Sie den PFAD ADJ. JIG an PT01 auf der
HAUPTPLATINE an.
2) Spielen Sie das SYNCHRONISATIONSBAND ab
(FARBBALKENSIGNAL ODER MONOSKOPSIGNAL).
3) Schließen Sie Kanal-1 des Oszilloskopfühlers an den
SCHALT-IMPULS-TESTPIN von PFAD ADJ. JIG an.
4) Schließen Sie Kanal-2 des Oszilloskopfühlers an die
VIDEO AUS auf der HAUPTPLATINE.
5) Spielen Sie das SYNCHRONISATIONSBAND
nochmals ab.
6) Stellen Sie das PG-Volumen auf einen Zeitintervall von
6,5Hz±0,5Hz zwischen Schaltimpuls und V-Sync-
Signal ein.
V.SYNC
Fig.49.
Abb.49.