Connecting Alarms
• A1,A2,A3,A4 (Alarm Input 1,2,3,4)
You can use external devices to signal the camera to react on events. Mechanical or
electrical switches can be wired to the A1,A2,A3,A4 (Alarm Input 1,2,3,4) and G (Ground)
connectors.
• G (Ground)
NOTE: All the connectors marked G or GND are common.
Connect the ground side of the alarm input and/or alarm output to the G (Ground)
connector.
• AO (Alarm Output)
The camera can activate external devices such as buzzers or lights. Connect the device to
the AO (Alarm Output) and G (Ground) connectors.
Connecting the Power
Connect power of 12VDC for the camera.
When using a 12VDC adapter, connect the positive (+) pole to the ' + ' position and the
negative (-) pole to the ' - ' position.
Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed Class 2 power source
only.
• Be careful not to reverse the polarity when you connect the power cable.
• You can also use the PoE (Power over Ethernet) injector to supply power to the
Network Connection & IP assignment
The eneo scanning device tool is used to locate all eneo network cameras in a local net-
work. The tool does not need to be installed with a setup program. The program exe-file
can be started directly from the CD with a simple double click to use the program.