Kind of problem
Electric Motor doesn't start
and no sounds are heard.
The motor doesn't turn in
any directions but sound
of the locking of the brake
GB
can be heard.
The elevator does not
support the load and
slides down.
10
TROUBLE SHOOTING
Probable cause
Is the motor receiving
enough power?
Has the elevator been
used considering the
intermittence of the
motor?
After a long period of
storage the motor doesn't
start.
Is the motor receiving
enough power?
Brake needs to be
regulated.
Elevator is overloaded.
Yes
Call the nearest service
centre.
Call the nearest service
centre.
Humidity has formed
internally on capacitor or
between the brake block
and brake block covering
making the two bind
together, elevator's brake
should be regulated to
ensure the brakes doesn't
bind on the brake block
cover.
Call the nearest service
centre.
Use the regulation tool.
Remove the load and use
the elevator only up to
200 kg.
No
Check connections.
Cool the motor and then
use the elevator as per
instructions.
Use in the normal manner
as explained in this
manual.
Check connections.
Call the nearest service
centre.