Angle sensors
en
5.1.6
Angle sensor 424SD
Angle sensor, 20‒360°, digital and/or analogue signal
Pos.
Example
1‒4
424S
5
D
6
0
7
7
8
D
9
S
10
180
001
11
B
For further details see the supplied datasheet.
Date: 09.06.2020
Meaning
Reference
Connection
Bearing
Output signal 1
Output signal 2
Digital output
Angle measuring
range
(omitted in the case
of selection K - out-
put signal 2)
At signal output "D" ● 3-digit meter number (assigned by elobau)
Actuation lever
9010020A00M - V01
● 424SD = angle sensor base number
● AMP plug (on request)
● D = Deutsch plug
● 0 = plain bearing
● 1 = ball bearing
● 0 = 1‒5 V
● 1 = 4‒20 mA
● 6 = 0.5‒4.5 V, radiometric
● 7 = 0.5‒4.5 V
● K = no signal, only digital output
● D = digital output signal
● K = no output signal
● H = high-side switch
● L = low-side switch
● S = Push Pull
● 3 digits (value = angle)
e.g. 180 = 180 degrees
● B = Lever installed
17/20