Verfügbare Sprachen

17 Selected channel of the wireless sensor
19 Outdoor humidity (wireless sensor)

6 Before starting operation

NOTICE
Avoid connectivity disruptions!
To avoid connectivity disruptions between the devices, consider the following points before starting
operation.
1. Place base station (receiver) and remote sensor (sender) together as close as possible.
2. Set up power supply for the base station and wait until the indoor temperature is displayed.
3. Set up power supply for the remote sensor.
4. Position the base station and the remote sensor within the effective transmission range.
5. Ensure that the base station and remote sensor are assigned to the same channel.
When changing batteries always change batteries in the main unit as well as all remote units and re-
place them in the correct order, so the remote connection can be re-established. If either of the
devices is mains-powered, the power supply must be disconnected for a short moment also for this
device when exchanging the batteries. If batteries are exchanged in only one of the devices (i.e. the
remote sensor) the signal can't be received or can't be received correctly.
Note, that the effective range is vastly affected by building materials and position of the main and re-
mote units. Due to external influences (various RC devices and other sources of interference), the
maximum distance can be greatly reduced. In such cases we suggest to position the main unit and the
remote sensor at other places. Sometimes all it takes is a relocation of one of these components of a
few inches!

7 Setting up power supply

Base station
1. Remove the battery compartment cover.
2. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
3. Replace the battery compartment cover.
4. Wait until the indoor temperature is displayed on the base station.
NOTICE! Alternatively, operation with mains power supply (DC 5V) is possible. Proceed as fol-
lows:
5. Insert the DC connector into the connection socket of the base station.
6. Insert the mains plug into the power outlet.
7. The device is energized directly.
8. Wait until the indoor temperature is displayed on the base station.
NOTICE! When switching from mains power supply to battery power supply or vice versa,
the power supply is being disabled for a short moment for technical reasons. In this process
all settings made previously, will be deleted.
Remote sensor
9. Loosen the screws at the battery compartment cover with a small Philips screwdriver and remove
the cover.
10. Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
11. Set the channel selector switch to the desired channel.