The flow medium to be monitored should preferably contain as few solid particles as possible.
Present particles must not exceed a diameter of 0.63 mm. If necessary, install a screen
filter!
•
The material of the devices is not suitable for monitoring oils. The strength of the used
plastic parts would be considerably reduced.
•
Attention:
The union nut of the transducer is sealed and must not be opened!
4
Installation in piping
Now you can install the flow sensor in the piping system which was prepared according to § 3.
Note:
•
Use only a suitable compound for sealing.
If you seal the male thread, take care that no fibrous sealing compounds get into the
turbine (hemp or Teflon strip).
4.1 Installation with connection adapters
At first screw-in the connection adapters into the tube.
Now install the turbine. Make sure that the provided seals fit properly and tighten the un-
ion nuts.
Technical changes reserved
(recommended installation type)