9.4.1 Manage sensors
Manage sensors
pH::lyser
chlori::lyser
Digital Input 1
Add sensor...
pH::lyser/0/1
Names of the connected sensors
chlori::lyser/0/2
Digital Input 1
Configured inputs (digital or analog)
Add sensor...
Add a new sensor
Sensor configuration
Select a sensor or an input with the [UP] and [DOWN] buttons.
Confirm with [OK].
– The "Sensor configuration" menu opens.
Sensor configuration
Configure...
Add parameters...
Remove sensor
Configure...
Select "Configure..." with the [Up] and [Down] buttons.
Confirm with [OK].
– The "Configure..." menu opens.
Configure...
Type:
The "Configure..." menu is available for analog and digital inputs.
If an analog input is chosen, the following settings can be
configured:
"0-20 mA"
"4-20 mA"
Configure...
Type:
Invert pol.:
Configure...
Type:
Interval [s]:
If a digital input is chosen, the following settings can be
configured:
"State": Depending on the contact type of the digital input, the
result is 1 or 0.
– The contact type of the digital input can be changed with
"Invert pol.: ".
"Count": Counts the digital pulses within the interval.
– The interval can be defined with "Interval [s]:
Adding a parameter
Add para.
Add pH
Add pH-mV
Add Temp
1. Select a parameter with the [Up] and [Down] buttons.
2. Confirm with [OK].
Removing a sensor
1. Select "Remove sensor" with the [Up] and [Down] buttons.
2. Confirm with [OK].
The sensor and the parameters for the sensor are removed. If an
input of a controller is linked to the sensor or parameter, the
controller is deactivated.
Adding a new sensor
1. Select "Add sensor..." in the "Manage sensors" menu with the
[Up] and [Down] buttons.
2. Confirm with [OK].
– The "Add new sensor" menu opens.
Add new sensor
Add 0/4-20mA...
Add digital in...
Add s::can Sensor...
To add an analog sensor select "Add 0/4-20mA..." with the
[Up] and [Down] buttons. Confirm with [OK].
4-20 mA
To add a digital sensor select "Add digital in..." with the [Up]
and [Down] buttons. Confirm with [OK].
To add an s::can sensor select "Add s::can Sensor..." with the
[Up] and [Down] buttons. Confirm with [OK].
– The port for a new sensor is searched and the new s::can
sensor is added to the sensor list automatically. No further
interaction is required.
After adding a sensor, a parameter has to be added. See section
Adding a
parameter.