maged. This equipment must not be used to clean
such surfaces. The equipment may only be used
by guiding it over the ground in a vertical position.
The equipment must not be used in a horizontal
position (e.g. walls) or overhead (e.g. ceiling). It
must not be used for unmade/unpaved surfaces
(e.g. grass pavers).
Use only the brush which is intended to be used
for the surface you want to clean. Test the brush
for suitability on an inconspicuous area fi rst
before using it each time. Diff erent brushes for
diff erent surfaces are available as separate ac-
cessories. Only use water without any additives
whatsoever.
The MEDIUM nylon brush (black) is specifi -
cally suitable for cleaning unsealed paver and
stone surfaces. It can therefore also be used for
cleaning surfaces which are paved with paving
stones/concrete blocks or concreted surfaces
(e.g. driveways, decks, paths). The side brush can
be used for cleaning perimeters and bases.
Using the SOFT nylon brush (yellow/green) the
equipment can also be used for cleaning wood,
composite materials (BPC/WPC) or for brushing
(e.g. fl attened areas) artifi cial turf to raise it up-
right, as used in the private domain where it is
installed, for example, on balconies or decks.
The ULTRA metal brush can be used for cleaning
robust surfaces such as, e.g. paving stones/
concrete blocks, concreted surfaces, granite or
porphyry to remove stubborn dirt.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
Anl_Picobella_SPK7.indb 23
Anl_Picobella_SPK7.indb 23
GB
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
4. Injury and damage to property caused by fl y-
ing parts.
Limit the operating time.
All stages of the operating cycle must be conside-
red (for example, times in which the electric tools
are switched off and times in which the tool is
switched on but operates without load).
Danger!
This electric power tool generates an electro-
magnetic fi eld during operation. Under certain
circumstances this fi eld may actively or passively
impede medical implants. To reduce the risk of
serious or fatal injuries, we recommend persons
with medical implants to consult their doctor and
the manufacturer of the medical implant prior to
using the equipment.
4. Technical data
Voltage ....................................................18 V d.c.
Speed n0 ...................................... 800-1400 rpm
Brush diameter ...................................... 115 mm
Protection class .................................................III
Sound power level LWA .................... 94.6 dB (A)
Uncertainty K ........................................ 3 dB (A)
Vibration ah .......................................... 2,13 m/s²
Uncertainty K ..........................................1.5 m/s
Weight ....................................................... 4,1 kg
Sound pressure level LpA at the operator's ear ...
........................................................... 83,8 dB (A)
Uncertainty K ........................................ 3 dB (A)
Max. water inlet pressure ............0.6 MPa (6 bar)
Power-X-Change lithium-ion batteries
Voltage: .................................................. 18 V DC
Capacity: ...................................................... 3 Ah
Number of cells: .............................................. 10
- 23 -