15. Maintenance schedule

Please adhere to the following maintenance periods in order to ensure a failure-free operation.
IMPORTANT! The equipment must be filled with engine oil and fuel before it is started.
Before each use
Checking the engine oil
Changing the engine oil
Checking the air filter
Cleaning the air filter
Cleaning the petrol filter
Visual inspection of the
equipment
Cleaning the spark plug
Checking andreadjusting
the throttle vale on the
carburetor
Cleaning the cylinder head
Set the valve play
Important: The positions marked with "x*" should only be carried out by an authorized dealer.

Service information

Please note that the following parts of this product are subject to normal or natural wear and that the following parts are therefore also required
for use as consumables.
Wear parts*: Spark plug
* Not necessarily included in the scope of delivery!
8
GB
After an operating
period of 20 hours
X
For the first time, then
every 50 hours
X
X
After an operat-
After an operating
ing period of 50
period of 100 hours
hours
X
X
X
Distance: 0.6
mm, replace if
necessary
After an oper-
ating period
of 300 hours
Change the
filter insert if
necessary
X*
X*
X*