5.5
Pressure loss
The product allows you to use a great variety of filter inserts. See the diagram
for the resulting pressure losses.
5.5.1
In suction mode with clean filter insert
5.5.2
In suction mode with filter insert polluted by 50 %
Mounting
A
B
D
C
Flow rate Q [l/h]
A
B
D
C
Flow rate Q [l/h]
A. Sintered plastic insert
35 µm
B. Sintered plastic insert
70 µm
C. Felt
D. Steel sieve
1. Sintered plastic insert
35 µm
2. Sintered plastic insert
70 µm
3. Felt
4. Steel sieve
FloCo-Top-1K
EN
16