Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Use; Technical Specifications - Rothenberger Industrial Roturbo 12000 Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

SCOPE OF USE

This appliance is designed for quick heating in large areas, marquees etc. It is not intended
for domestic use and it may only be used outside or in well ventilated rooms. Use of the
product for any other purpose and / or modification of the product count as misuse and can
be highly dangerous and is forbidden.
Only for quick pre-heating. This appliance is not intended for reaching or maintaining a certain
temperature level within an enclosed space.
For industrial use, a hose failure safety device has to be fitted to the appliance. For Roturbo
35000 and 35000 SA, this valve is pre-assembled with the gas pressure regulator. For the
other items, it can be purchased from the manufacturer.
This appliance may only be used with propane or with propane-butane mixtures and with a
regulator with a constant output pressure of 300 mbar (Roturbo 12000, 19000) respectively
1500 mbar (Roturbo 35000, 35000 SA). This appliance shall only be used with LPG refillable
cylinders (different sizes in different countries, e.g. Germany 5 kg, 11 kg or 33 kg). It can be
dangerous to connect the burner to other types of gas containers.
Always make sure that the regulator and the hose used for this appliance are certified.

TECHNICAL SPECIFICATIONS

Gas category - gas type
Countries of destination
(I3B/P or I3P):
Operating pressure
Injector diametre
Heat input (I3B/P)
Heat input (I3P)
Gas consumption
Flame temperature:
Air output
Air delivery temperature
classification
Mains Voltage
Rated power
Protection category
Insulation class
Safety features
The burner may not be used without a constant pressure regulator fitted.
This appliance shall only be used with LPG refillable cylinders and only in the
open or in well-ventilated rooms. Keep children away from the device!
Insulation class I
Roturbo 12000 Roturbo 19000 Roturbo 35000 Roturbo 35000 SA
I3B/P - propane / butane, I3P - propane
AL, AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES,
FI, FR, GB, GR, HU, HR, IE, IT, IS, LV, LT, LU,
MK, MT, NL, NO, PL, PT, RO, SE, SI, SK, TR
300 mbar
1.0 mm
1.18 mm
13.3 kW
18.2 kW
11.9 kW
16.0 kW
970 g/h
1325 g/h
930 °C
980 °C
500 m
/ h
3
32 K
39 W
Overheat protection,
safety cut-out
12
34.0 kW
29.0 kW
2460 g/h
48 K
230 V~ / 50 Hz
IPX4; motor IP44
I
Overheat protection,
hose failure safety device
1500 mbar
1.15 mm
19.0 – 34.0 kW
17.0 – 29.0 kW
1375 – 2460 g/h
1000 °C
800 m
/h
3
53 K
65 W
safety cut-out,

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis