Herunterladen Inhalt Inhalt Diese Seite drucken

Abicor Binzel EWR PRO Betriebsanleitung Seite 20

Gassparsystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2 Product description
2 Product description
2.1 Designated use
2.2 Use contrary to the designated use
2.3 Technical Data
Ambient temperature
Transport and storage
Relative humidity
Ambient temperature
Tab. 2
Weight
Dimensions (mm) LxWxH
Rated electrical values
Starting idling volume
Flow rate
General data
Tab. 3
Inlet pressure
2 - 6 bar
3 - 6 bar
4 - 6 bar
at pressures <2 bar, the EWR is switched off.
Pressure values
Tab. 4
EN - 4
The gas monitoring system EWR RPO/BASIC must be used for manual
welding and also for automatic use. It forms part of the welding system and
may only be operated in it. Designated use also includes the observance of the
prescribed operating, maintenance and servicing instructions.
Any use other than that described under "Designated Use" is considered
contrary to the designated use. Unauthorised conversions or power increase
modifications are not allowed.
NOTICE
• The inlet pressure may not exceed 6 bar.
+ 5 °C to + 50 °C
- 10 °C to + 55 °C
up to 90 % at 20 °C
EWR RPO/BASIC MIG/MAG
approx. 1.3 kg
118x148x58 mm
24 VDC, 450 mA - 750 mA
0.2 - 2.0 bar: 5 - 23 l/min
5 - 30 l/min
Outlet pressure
up to 0.6 bar
up to 1.2 bar
up to 2.0 bar
EWR RPO/BASIC
10,6 - 63,6 cfh

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ewr basic

Inhaltsverzeichnis