Seite 1
MHWKY 15 October 2010 Dell M8428-k Getting Started Guide 使用入门指南 入門指南 Guide de mise en route Handbuch zum Einstieg Panduan Pengaktifan はじめに 시작 안내서 Guia de Noções Básicas Guía de introducción Başlangıç Kılavuzu 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 2
Downloaded from www.Manualslib.com manuals search engine...
Seite 3
MHWKY 15 October 2010 Dell M8428-k Getting Started Guide 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 4
Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect, and Dell OpenManage are trademarks of Dell Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries; Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
Seite 5
Dell M8428-k quickly. For detailed installation and configuration instructions, see the Dell M8424-k Hardware Reference Manual. NOTE Throughout this document, the Dell M8428-k is referred to as the converged network switch or the switch module. It is also called the M8428-k 10GbEE-FCOE/8Gb FC SW. Unpacking and installing the converged network switch If the converged network switch is installed in the Blade Server Enclosure that is shipped to you, skip this section.
Seite 6
SFP transceivers and compatible fibre cables, as required. The switch module can also use twin-ax copper cables. NOTE Use only Dell-approved SFPs on the external ports of this module. • Access to an FTP server for backing up the converged network switch configuration.
Seite 7
Blade Server Enclosure CMC graphical user interface (GUI). • Dell M8428-k command line interface (CLI). After modifying the switch module’s IP address and domain name (if the switch module is in full fabric mode), we recommend that you cable all external ports to fabric connections before bringing the switch module online.
Seite 8
Refer to the documentation for the CMC GUI application for additional detail. Using the Dell M8428-k CLI to set the IP address Use the following tasks to change the IP address on the switch module using the module’s CLI. Follow the first few steps to establish a terminal emulation session between the switch module and a Blade Server Enclosure management workstation used for managing the switch module.
Seite 9
1. Login to the switch. 2. Enter the following command: cmsh 3. Once in the command shell, enter the following command: enable 4. Enter the following command: conf t Dell M8428-k Getting Started Guide 7 of 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 10
Orient the transceiver correctly and insert it into a port until it is firmly seated and the latching mechanism clicks. For instructions specific to the type of transceiver, refer to the transceiver manufacturer’s documentation. 8 of 160 Dell M8428-k Getting Started Guide MHWKY Downloaded from www.Manualslib.com...
Seite 11
Repeat for the remaining transceivers as required. 4. Check the LEDs to verify that all components are functional. For information about LED patterns, see the “Operating the converged network switch” chapter in the Dell M8428-k Hardware Reference Manual. 5. Verify the correct operation of the converged network switch by typing the switchShow command from the workstation.
Seite 12
Changing to full fabric mode using the Command Line Interface Complete the following steps to enable NPIV mode using the CLI. 1. Log in using the default administrative account. Login: admin Password: password 10 of 160 Dell M8428-k Getting Started Guide MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 13
4. From the Fabric Tree, select the converged network switch. The selected switch module appears in the Switch View. 5. Click the Switch Admin button in the browser-based GUI Manage task box. The Switch Administration window opens. Dell M8428-k Getting Started Guide 11 of 160 MHWKY Downloaded from www.Manualslib.com...
Seite 14
Access Gateway mode is enabled. You can also enter the ag ––mapshow command to display the F_Port to N_Port mapping. Enter ag ––help command to display a list of all NPIV actions. 12 of 160 Dell M8428-k Getting Started Guide MHWKY Downloaded from www.Manualslib.com...
Seite 15
These commands upload the switch module configurations to the server, making it available for downloading to a replacement switch module if necessary. Dell recommends backing up the configuration on a regular basis to ensure that a complete configuration is available for downloading to a replacement switch module.
Seite 16
14 of 160 Dell M8428-k Getting Started Guide MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 17
MHWKY 2010 年 10 月 15 日 Dell M8428-k 《使用入门指南》 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 18
未经 Dell Inc. 书面许可,严禁以任何形式复制这些材料。 本文中使用的商标:Dell、 DELL 徽标、 Inspiron、 Dell Precision、 Dimension、 OptiPlex、 Latitude、 PowerEdge、 PowerVault、 PowerApp、 PowerConnect、和 Dell OpenManage 是 Dell Inc. 的商标; Intel、Pentium、和 Celeron 是 Intel Corporation 在美国 和其他国家或地区的注册商 标; Microsoft、Windows、Windows Server、MS-DOS 和 Windows Vista 是 Microsoft Corporation 在美国和 / 或其他国家或地区的商标或注册...
MHWKY 15 Octobre 2010 Dell M8428-k Guide de mise en route 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 42
D'autres marques commerciales et noms de marque peuvent être utilisés dans ce document pour faire référence aux entités se réclamant de ces marques et de ces noms ou de leurs produits. Dell Inc. rejette tout intérêt exclusif dans les marques et les noms commerciaux autres que les siens.
Seite 43
Dell M8424-k Hardware Reference Manual (Manuel de référence du matériel Dell M8424-k). REMARQUE Dans la totalité ce de document, il est fait référence au Dell M8428-k comme au converged network switch ou au switch module. Il est également dénommé M8428-k 10GbEE-FCOE/8Gb FC SW. Déballage et installation du converged network switch Si le converged network switch est installé...
Seite 44
Les émetteurs-récepteurs SFP et câbles fibre optique, au besoin. The switch module peut également utiliser des câbles bi-ax en cuivre. REMARQUE N'utilisez que des SFP approuvés par Dell sur les ports externes de ce module. • L'accès à un serveur FTP pour la sauvegarde de la configuration du converged network switch.
Seite 45
3. Saisissez les nouvelles informations appropriées dans les champs IP Address (Adresse IP), Subnet Mask (Masque de sous-réseau) et Gateway (Passerelle), puis cliquez sur Apply (Appliquer). 4. Pour activer DHCP, sélectionnez DHCP Enabled (DHCP activé) puis cliquez sur Apply (Appliquer). Dell M8428-k Guide de mise en route 43 sur 160 MHWKY Downloaded from www.Manualslib.com...
Seite 46
Voir la documentation de l'application GUI CMC pour obtenir des détails supplémentaires. Utilisation de l'interface CLI du Dell M8428-k pour définir l'adresse IP Effectuez les tâches suivantes pour modifier l'adresse IP du switch module à l'aide de l'interface CLI du module.
Seite 47
1. Connectez-vous au commutateur. 2. Entrez la commande suivante : cmsh 3. À partir du shell de commande, entrez la commande suivante : enable Dell M8428-k Guide de mise en route 45 sur 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 48
REMARQUE Tant que la configuration n'est pas terminée, assurez-vous que le switch module n'est pas en cours de modification par l'intermédiaire d'une autre connexion. 46 de 160 Dell M8428-k Guide de mise en route MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 49
Répétez les sous-étapes a, b, et c pour les ports restants, au besoin. REMARQUE N'utilisez que des SFP approuvés par Dell sur les ports externes de ce module. 3. Branchez les câbles aux émetteurs-récepteurs. Les émetteurs-récepteurs sont munis de détrompeurs qui assurent une orientation correcte. Si un émetteur-récepteur ne s'installe pas facilement, assurez-vous qu'il est bien orienté...
Seite 50
Cette commande charge la configuration du converged network switch sur le serveur, la rendant disponible pour téléchargement vers un converged network switch de rechange, le cas échéant. Dell vous recommande de sauvegarder régulièrement la configuration afin d'assurer la disponibilité d'une configuration complète pour téléchargement vers un switch module de rechange.
Seite 51
Une fois le converged network switch activé en mode NPIV, seul un sous-ensemble limité des commandes du système d'exploitation de la matrice est disponible et toutes les demandes de service associées à la matrices sont transmises aux commutateurs de la matrice. Dell M8428-k Guide de mise en route 49 sur 160 MHWKY Downloaded from www.Manualslib.com...
Seite 52
4. Entrez la commande suivante pour activer le mode NPIV : ag ––modeEnable Le switch module redémarre automatiquement et revient en ligne en mode NPIV utilisant un mappage par défaut Port_F à Port_N. 50 de 160 Dell M8428-k Guide de mise en route MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 53
Ces commandes permettent de charger les configurations du switch module, ce qui le rend disponible pour téléchargement sur un switch module de rechange, le cas échéant. Dell vous recommande de sauvegarder régulièrement la configuration afin d'assurer la disponibilité d'une configuration complète pour téléchargement sur un module de commutateur de rechange.
Seite 54
52 de 160 Dell M8428-k Guide de mise en route MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 55
MHWKY 15. Oktober 2010 Dell M8428-k Handbuch zum Einstieg 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 56
In diesem Text verwendete Marken: Dell, das DELL Logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect und Dell OpenManage sind Marken von Dell Inc.; Intel, Pentium, und Celeron sind eingetragene Marken von Intel Corporation in den USA und anderen Ländern, Microsoft, Windows, Windows Server, MS-DOS und Windows Vista sind entweder Marken oder eingetragene Marken von Microsoft Corporation in den USA und/oder anderen Ländern.
Übersicht Diese Handbuch zum Einstieg bietet einen Überblick für erfahrene Benutzer, um sie dabei zu unterstützen, Dell M8428-k schnell zu entpacken, zu installieren und zu konfigurieren. Detaillierte Installations- und Konfigura- tionsanweisungen finden Sie im Dell M8424-k-Hardware-Referenzhandbuch. ANMERKUNG In diesem Dokument wird Dell M8428-k als konvergierter Network-Switch oder Switch-Modul bezeichnet. Es wird außerdem als M8428-k 10GbEE-FCOE/8Gb FC SW bezeichnet.
• SFP-Transceiver (Sender-Empfänger) und kompatible Glasfaserkabel wie erforderlich. Der Switch-Modul akzep- tiert auch Doppelaxialkabel. ANMERKUNG Verwenden Sie ausschließlich von Dell zugelassene SFPs auf den externen Ports dieses Moduls. • Zugang zu einem FTP-Server zur Sicherung der konvergierter Network-Switch Konfiguration. •...
Seite 59
3. Geben Sie die neuen Informationen in Felder IP Address (IP-Adresse), Subnet Mask (Sunetzmaske) und Gateway ein wie jeweils passend und klicken Sie auf Apply (Anwenden). 4. Wählen Sie zum Aktivieren von DHCP DHCP Enabled (DHCP aktiviert) aus und klicken Sie auf Apply (Anwenden). Dell M8428-k - Handbuch zum Einstieg 57 von 160 MHWKY Downloaded from www.Manualslib.com...
Seite 60
ANMERKUNG Weitere Informationen finden Sie in der Dokumenation zur CMC-GUI-Anwendung. Verwenden der Dell M8428-k-Befehlszeilenschnittstelle zum Einstellen der IP-Adresse Gehen Sie wie folgt vor, um die IP-Adresse auf dem Switch-Modul unter Verwendung der CLI des Moduls zu ändern: Verwenden Sie diese ersten Schritte beim Aufbau einer Terminalemulationssitzung zwischen dem Switch-Modul und einer Blade Server-Gehäuseverwaltungs-Workstation, die für die Verwaltung von Switch-Modul verwendet wird.
Seite 61
DHCP [Off]: IP address is being changed...Done (IP-Adresse wird geändert...Fertig). 6. Geben Sie in der Eingabeaufforderung ipAddrShow ein, um zu überprüfen, dass die Adresse richtig eingestellt wurde. Dell M8428-k - Handbuch zum Einstieg 59 von 160 MHWKY Downloaded from www.Manualslib.com...
Seite 62
Weitere Informationen zur CEE-CLI-Schnittstelle und zur Konfiguration von Switches für den FCoE-Betrieb finden Sie im Converged Enhanced Ethernet-Administratorhandbuch. In der Converged Enhanced Ethernet-Befehlsreferenz finden Sie weitere Details zu den Befehlen. 60 von 160 Dell M8428-k - Handbuch zum Einstieg MHWKY Downloaded from www.Manualslib.com...
Seite 63
Wiederholen Sie für die verbleibenden Ports die Unterschritte a, b und c wie erforderlich. ANMERKUNG Verwenden Sie ausschließlich von Dell zugelassene SFPs auf den externen optischen Ports dieses Moduls. 3. Verbinden Sie die Kabel mit den Sender-Empfängern. Die Sender-Empfängers sind codiert, um die richtige Ausrichtung sicherzustellen. Wenn sich ein Sender-Emp- fänger nicht einfach installieren lässt, dann stellen Sie sicher, dass er ordnungsgemäß...
Seite 64
Wiederholen Sie dies für die verbleibenden Sender-Empfänger, wie erforderlich. 4. Überprüfen Sie die LEDs, um die Funktionstüchtigkeit aller Komponenten zu bestätigen. Weitere Informationen zu LED-Mustern finden Sie im Kapitel „Betrieb des konvergierter Network-Switch“ im Dell M8428-k-Hardware-Referenzhandbuch. 5. Überprüfen Sie die ordnungsgemäße Funktionsweise des konvergierter Network-Switch, indem Sie von der Workstation aus den Befehl switchShow eintippen.
Seite 65
––modeDisable Der Switch-Modul wird automatisch neu gestartet und ist anschließend im Online-Full-Fabric-Modus verfügbar. Die NPIV-Parameter, wie z. B. die Port-Zuweisung sowie Failover und Failback, werden automatisch entfernt. Dell M8428-k - Handbuch zum Einstieg 63 von 160 MHWKY Downloaded from www.Manualslib.com...
Seite 66
(Erweiterten Modus anzeigen), die sich rechts oben im Fenster „Switch Administration“ (Switch-Verwaltung) befindet. Klicken Sie auf die Registerkarte Configure (Konfigurieren) und dann auf die Registerkarte Upload/Download (Upload/Download). Geben Sie die relevanten Informationen ein, um die Konfigurationsdatei hochzuladen. 64 von 160 Dell M8428-k - Handbuch zum Einstieg MHWKY Downloaded from www.Manualslib.com...
Seite 67
Access Gateway mode is enabled (Access-Gateway ist aktiviert). Sie können auch den Befehl ag ––mapshow eingeben, um die F_Port-zu-N_Port-Zuweisung anzuzeigen. Geben Sie den Befehl ag ––help ein, um eine Liste aller NPIV-Aktionen anzuzeigen. Dell M8428-k - Handbuch zum Einstieg 65 von 160 MHWKY Downloaded from www.Manualslib.com...
Seite 68
Mit diesen Befehlen wird die Switch-Modul-Konfiguration auf den Server hochgeladen. Sie kann damit bei Bedarf auf ein Ersatz-Switch-Modul heruntergeladen werden. Dell empfiehlt, dass Sie die Konfiguration regelmäßig sichern, um zu gewährleisten, dass eine vollständige Konfi- guration auf ein Austausch-Switch-Modul heruntergeladen werden kann.
Seite 69
MHWKY 15 Oktober 2010 Dell M8428-k Panduan Pengaktifan 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 70
Dilarang keras memperbanyak materi ini dengan cara apa pun tanpa izin tertulis dari Dell Inc. Merek dagang yang digunakan di dalam panduan ini: Dell, logo DELL, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect, dan Dell OpenManage merupakan merek dagang dari Dell Inc.; Intel, Pentium, dan Celeron merupakan merek dagang terdaftar dari Intel Corporation di Amerika Serikat dan negara-negara lain;...
Seite 71
Dell M8428-k dengan cepat. Untuk petunjuk lengkap tentang penginstalan dan konfigurasi, lihat Manual Referenso Perangkat Keras Dell M8424-k. CATATAN Di sepanjang dokumen ini, Dell M8428-k disebut sebagai switch jaringan konvergensi atau Switch. Juga dapat disebut M8428-k 10GbEE-FCOE/8Gb FC SW. Membuka dan memasang switch jaringan konvergensi Jika switch jaringan konvergensi dipasang dalam Blade Server Enclosure yang dikirimkan pada Anda, lewati lah bagian ini.
Seite 72
Pemancar-penerima SFP dan kabel serat yang cocok, sesuai keperluan. Switch juga dapat menggunakan kabel tembaga twin-ax. CATATAN Gunakan hanya SFP yang disetujui Dell pada port eksternal modul ini. • Akseslah server FTP untuk memback up konfigurasi switch jaringan konvergensi. •...
Seite 73
Blade Server Enclosure CMC graphical user interface (GUI). • Dell M8428-k command line interface (CLI). Setelah mengubah nama domain dan alamat IP Switch (jika Switch berada dalam mode rangka utuh), kami menganjurkan agar Anda menghubungkan semua port eksternal dengan kabel pada koneksi rangka sebelum Switch online.
Seite 74
CATATAN Lihat aplikasi CMC GUI untuk perincian lebih lanjut. Menggunakan Dell M8428-k untuk mengatur alamat IP Gunakan tugas berikut ini untuk mengubah alamat IP pada Switch dengan menggunakan CLI modul. Ikuti beberapa pertama untuk membuat sesi emulasi terminal antara Switch dan workstation manajemen Blade Server yang digunakan untuk mengelola Switch.
Seite 75
1. Masuk ke switch. 2. Masukkan perintah berikut: cmsh 3. Setelah masuk ke command shell, masukkan perintah berikut: enable (Aktifkan) 4. Masukkan perintah berikut: conf t Panduan Pengaktifan Dell M8428-k 73 dari 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 76
Pastikan Anda memiliki semua pemancar-penerima SFP yang diperlukan serta kabel tembaga twin-ax aktif ataupun optik. a. Lepaskan colokan debu dari port yang akan digunakan. b. Jika perlu, lepaskan tutup ujung dari SFP. 74 dari 160 Panduan Pengaktifan Dell M8428-k MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 77
Ulangi sublangkah a, b, dan c untuk port-port yang lain, sesuai keperluan. CATATAN Gunakan hanya SFP yang disetujui Dell pada port optik eksternal modul ini. 3. Sambungkan kabel-kabel pada pemancar-penerima. Pemancar-penerima dilengkapi kunci untuk memastikan orientasi yang benar. Jika pemancar-penerima tidak terpasang dengan mudah, pastikan sudah diarahkan dengan benar dan tutup ujung telah dilepaskan.
Seite 78
9. Ketika diminta, klik Yes (Ya) untuk menyalakan ulang Switch dalam mode rangka utuh. Sesi GUI berbasis browser ditutup; luncurkan lagi GUI berbasis browser setelah Switch melakukan booting ulang. 76 dari 160 Panduan Pengaktifan Dell M8428-k MHWKY Downloaded from www.Manualslib.com...
Seite 79
F_Port ke N_Port. Setelah Anda mengaktifkan switch jaringan konvergensi dalam mode NPIV, hanya tersedia subset perintah sistem operasi yang terbatas, dan semua permintaan layanan terkait rangka akan diteruskan ke switch rangka. Panduan Pengaktifan Dell M8428-k 77 dari 160 MHWKY Downloaded from www.Manualslib.com...
Seite 80
4. Masukkan perintah berikut untuk mengaktifkan mode NPIV: ag ––modeEnable Switch otomatis melakukan booting ulang dan kembali online dalam mode NPIV dengan menggunakan standar pabrik pemetaan F_Port ke N_Port. 78 dari 160 Panduan Pengaktifan Dell M8428-k MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 81
Ketika Anda memasukkan password, prosedur penyalinan akan dimulai. Perintah ini mengunggah konfigurasi modul ke server, membuatnya siap diunduh pada modul switch pengganti jika perlu. Dell merekomendasikan pembuatan cadangan data konfigurasi secara teratur untuk memastikan konfigurasi yang lengkap siap diunduh untuk modul switch pengganti. Panduan Pengaktifan Dell M8428-k...
Seite 82
80 dari 160 Panduan Pengaktifan Dell M8428-k MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 83
MHWKY 2010 Dell M8428-k はじめに 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 84
Pentium Celeron Intel Corporation 登録商標です。 、 、 、 および は、いずれも米国および またはその他の国における Microsoft Windows Windows Server MS-DOS Windows Vista の商標または登録商標です。 Microsoft Corporation 商標または製品の権利を主張する事業体を表すためにその他の商標および社名が使用されていることがあります。それらの商標や会社名は、一切 Dell Inc. に帰属するものではありません。 規制適合モデルコード: M8428-k 『はじめに』 82 / 160 Dell M8428-k MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 94
5. ag ––modeShow NPIV ag --modeShow Access Gateway mode is enabled. ag ––mapshow F_Port to N_Port ag ––help NPIV 設定のバックアップ Telnet configUpload CEE CLI cmsh copy running-config ftp://[username@server/path] Dell 『はじめに』 92 / 160 Dell M8428-k MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 95
MHWKY 2010 년 10 월 15 일 Dell M8428-k 시작 안내서 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 96
본 설명서에 사용된 상표 : Dell, DELL 로그 , Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, PowerConnect, 및 Dell OpenManage 는 Dell Inc. 의 상표입니다 . Intel, Pentium, 및 Celeron 은 미국 및 다른 국가들에서 Intel Corporation 의 등...
Seite 97
Blade Server 주 Dell M1000e Blade Server B1/B2 C1/C2 하드웨어 소유자 매뉴얼 . Blade Server Blade Server Blade Server , Blade Server 하드웨어 소유자 매뉴얼 주 Dell M8428-k 시작 안내서 95 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 98
Blade Server 융합 네트워크 스위치의 IP 주소 변경 255.255.255.0 10.77.77.77 0.0.0.0 , IP • Blade Server CMC CLI. • Blade Server (GUI). • Dell M8428-k (CLI) 96 / 160 Dell M8428-k 시작 안내서 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 99
I/O Module Overview (I/O 1. CMC ) 탭 엽 Setup( 2. CMC 3. IP 주소 , 서브넷 마스크 , 게이트웨이 력 Apply( 선택 4. DHCP , DHCP Enabled(DHCP Apply( Dell M8428-k 시작 안내서 97 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 100
급모 1 탭 주 추 CMC GUI Dell M8428-k CLI 를 이용하여 IP 주소 설정하기 몇 Blade Server . 일 Blade Server , Blade 구성 설명서 Server (LINUX UNIX TERM HyperTerminal . CLI Windows 95, 98, 2000, XP, NT, 2003 2008 a.
Seite 101
IP address is being changed...Done. 력 ipAddrShow FCoE 구성 최 종료 쉘 . FCoE , CEE 야 였 , cmsh 쉘 력 cmsh 쉘 력 enable 력 conf t 력 Dell M8428-k 시작 안내서 99 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 102
력 ––modeShow 1. admin Telnet 2. SFP 광 (twin-ax) 먼 엔 캡 , SFP 향 맞춘 히 딸깍 낼 특 , 남아 복 a, b, c 100 / 160 Dell M8428-k 시작 안내서 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 103
( 커넥 쪽 돌출 롯 커넥 향 맞춥 딸깍 낼 특 남아 복 4. LEDs 턴 Dell M8428-k 하드웨어 참조 설명서 " " 력 switchShow 력 fabricShow 력 configUpload . Dell NPIV 모드에서 전체 패브릭 모드로 변경 현 ( 출...
Seite 104
력 ag ––modeDisable 팅 들 , 핑 애극복 (failover) 애복 (failback) NPIV 력 ––modeShow NPIV ag ––modeShow 답 아야 Access Gateway mode is NOT enabled. 102 / 160 Dell M8428-k 시작 안내서 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 105
Disable( NPIV , Enable( 8. Apply( 표 Yes( NPIV 현재의 브라우저 기반 GUI 세션이 닫힙니다 . 스위치 모듈이 재부팅된 후 브라우저 기반 GUI 를 재시작합니다 . Dell M8428-k 시작 안내서 103 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 106
1. Telnet 력 configUpload 일 표 료 력 CEE CLI cmsh 5. 현 력 copy running-config ftp://[username@server/path] 암 표 암 력 , 복 며 , Dell 104 / 160 Dell M8428-k 시작 안내서 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 107
MHWKY 15 de outubro de 2010 Dell M8428-k Guia de Noções Básicas 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 108
Outras marcas e nomes comerciais podem ser usados neste documento como referência às entidades que reivindicam essas marcas e nomes ou a seus produtos. A Dell Inc. renuncia ao direito de qualquer participação em nomes e marcas comerciais que não sejam de sua propriedade.
Seite 109
Dell M8424-k Hardware Reference Manual (Manual de referência do hardware Dell M8424-k) NOTA Em todo este documento, iremos nos referir ao Dell M8428-k como a switch de rede convergente ou o módulo de comutador. Ele é também chamado de M8428-k 10GbEE-FCOE/8Gb FC SW.
Seite 110
Transceptores SFP e cabos de fibra compatíveis, conforme necessário. O módulo de comutador pode usar também cabos de cobre twinax. NOTA Use apenas SFPs aprovados pela Dell nas portas externas deste módulo. • Acesso a um servidor FTP para fazer backup da configuração do switch de rede convergente.
Seite 111
Interface gráfica do CMC do gabinete de servidor blade. • Interface de linha de comando do Dell M8428-k. Depois que você modificar o endereço IP e o nome de domínio do módulo de comutador (se o módulo de comutador estiver no modo de malha completa), nós recomendamos que você conecte todas as portas externas a conexões da malha antes de colocar o módulo de comutador online.
Seite 112
Consulte a documentação da interface gráfica do CMC para obter mais detalhes. Usar a interface de linha de comando do Dell M8428-k para definir o endereço IP Use as tarefas a seguir para alterar o endereço IP do módulo de comutador usando a interface de linha de comando do módulo.
Seite 113
Fibre Channel Subnetmask [none]: Gateway IP Address [0.0.0.0]:10.32.48.1 DHCP [Off]: IP address is being changed...Done. 6. Digite ipAddrShow no prompt para verificar se o endereço foi definido corretamente. Guia de Noções Básicas do Dell M8428-k 111 de 160 MHWKY Downloaded from www.Manualslib.com...
Seite 114
FCoE, e consulte Converged Enhanced Ethernet Command Reference (Guia de referência de comandos da Converged Enhanced Ethernet) para obter mais detalhes sobre os comandos. 112 de 160 Guia de Noções Básicas do Dell M8428-k MHWKY Downloaded from www.Manualslib.com...
Seite 115
Repita as sub-etapas a, b e c para as portas restantes, conforme necessário. NOTA Use apenas SFPs aprovados pela Dell nas portas óticas externas deste módulo. 3. Conecte os cabos aos transceptores. Os transceptores têm formatos especiais para garantir a orientação correta. Se você não conseguir instalar um transceptor com facilidade, verifique se a orientação do mesmo está...
Seite 116
Este comando faz o upload da configuração do switch de rede convergente no servidor, disponibilizando-o para download em um switch de rede convergente de reposição, se necessário. A Dell recomenda que você faça regularmente o backup da configuração para garantir que uma configuração completa esteja disponível para download em um módulo de comutador de reposição.
Seite 117
Você pode digitar o comando ag ––modeShow para confirmar que módulo está no modo NPIV. ag ––modeShow A resposta deve ser: Access Gateway mode is NOT enabled (O modo Gateway de acesso NÃO está ativado). Guia de Noções Básicas do Dell M8428-k 115 de 160 MHWKY Downloaded from www.Manualslib.com...
Seite 118
9. Quando solicitado, clique em Yes (Sim) para reinicializar o módulo de comutador no modo NPIV. A sessão de interface Web é fechada; reabra a interface Web depois que o módulo de comutador for reinicializado. 116 de 160 Guia de Noções Básicas do Dell M8428-k MHWKY Downloaded from www.Manualslib.com...
Seite 119
5. Digite o seguinte comando para fazer o upload da configuração de CEE atual: copy running-config ftp://[username@server/path] Você será solicitado a fornecer uma senha. Quando você digitar a senha, o procedimento de cópia começará. Guia de Noções Básicas do Dell M8428-k 117 de 160 MHWKY Downloaded from www.Manualslib.com...
Seite 120
Estes comandos fazem o upload das configurações do módulo comutador para o servidor, disponibilizando-o para download em um módulo comutador de reposição, se necessário. A Dell recomenda que você faça regularmente o backup da configuração para garantir que haverá uma configuração completa disponível para download em um módulo comutador de reposição.
MHWKY 15 de octubre de 2010 Dell M8428-k Guía de introducción 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
(Manual de referencia de hardware de Dell M8424-k). NOTA En este documento, se hace referencia a Dell M8428-k como el conmutador de red convergente o el módulo conmutador. También se denomina M8428-k 10GbEE-FCOE/8Gb FC SW. Cómo desempaquetar e instalar el conmutador de red convergente Si el conmutador de red convergente está...
Seite 124
Transceptores SFP y cables de fibra compatibles, según sea necesario. El módulo conmutador también puede utilizar cables axiales dobles de cobre. NOTA Utilice sólo SFP aprobados por Dell en los puertos externos de este módulo. • Acceso a un servidor FTP para realizar copia de seguridad de la configuración del conmutador de red convergente.
Seite 125
Interfaz gráfica de usuario (GUI) de CMC del gabinete del servidor Blade. • Dell M8428-k interfaz de línea de comandos (CLI) Después de modificar la dirección IP del módulo conmutador y el nombre del dominio (si el módulo conmutador se encuentra en el modo de red fabric completa, le recomendamos que conecte por cable todos los puertos externos a las conexiones de la red fabric antes de conectar el módulo conmutador en línea.
Seite 126
Consulte la documentación acerca de la aplicación de la GUI CMC para obtener más información. Uso de la CLI de Dell M8428-k para establecer la dirección IP Utilice las siguientes tareas para cambiar la dirección IP del módulo conmutador mediante la CLI del módulo. Siga los primeros pasos para establecer una sesión de emulación de terminal entre el módulo conmutador y una...
Seite 127
Gateway IP Address [0.0.0.0]:10.32.48.1 DHCP [Off] ([Desactivado]): IP address is being changed...Done. 6. Especifique ipAddrShow en el indicador para verificar que la dirección se haya establecido correctamente. Guía de introducción de Dell M8428-k 125 de 160 MHWKY Downloaded from www.Manualslib.com...
Seite 128
Ethernet) para obtener información acerca de la interfaz de la CLI de CEE y la configuración de conmutadores para el funcionamiento de FCoE, y consulte Converged Enhanced Ethernet Command Reference (Referencia del comando de Converged Enhanced Ethernet) para obtener más información sobre los comandos. 126 de 160 Guía de introducción de Dell M8428-k MHWKY Downloaded from www.Manualslib.com...
Seite 129
Repita los subpasos a, b y c con los puertos restantes, según sea necesario. NOTA Utilice sólo SFP aprobados por Dell en los puertos ópticos externos de este módulo. 3. Conecte los cables a los transceptores. Los transceptores se adaptan para garantizar una orientación correcta. Si un transceptor no se instala fácilmente, asegúrese de que esté...
Seite 130
Para obtener información sobre los patrones de LED, ver “Funcionamiento del conmutador de red convergente” en el Dell M8428-k Hardware Reference Manual (Manual de referencia del hardware de Dell M8428-k). 5. Verifique el funcionamiento correcto del conmutador de red convergente especificando el comando switchShow en la estación de trabajo.
Seite 131
Puede introducir el comando ag ––modeShow para garantizar que el módulo se encuentra en el modo NPIV. ag ––modeShow La respuesta debería ser: Access Gateway mode is NOT enabled (El modo de acceso de puerta de enlace NO está activado). Guía de introducción de Dell M8428-k 129 de 160 MHWKY Downloaded from www.Manualslib.com...
Seite 132
9. Cuando se le solicite, haga clic en Yes (Sí) para reiniciar e módulo conmutador en el modo NPIV. La sesión actual de la GUI basada en el explorador se cerrará; vuelva a iniciarla cuando módulo conmutador se reinicie. 130 de 160 Guía de introducción de Dell M8428-k MHWKY Downloaded from www.Manualslib.com...
Seite 133
5. Introduzca el comando siguiente para cargar la configuración de CEE actual: copy running-config ftp://[nombre_de_usuario@server/path] Se le solicitará una contraseña. Cuando introduzca la contraseña, se iniciará el proceso de copia. Guía de introducción de Dell M8428-k 131 de 160 MHWKY Downloaded from www.Manualslib.com...
Seite 134
Es recomendable realizar una copia de seguridad de la configuración de forma periódica para garantizar que esté disponible para descarga una configuración completa en un módulo conmutador de recambio. 132 de 160 Guía de introducción de Dell M8428-k MHWKY Downloaded from www.Manualslib.com...
Seite 135
MHWKY 15 Ekim 2010 Dell M8428-k Başlangıç Kılavuzu 53-1002029-01 *53-1002029-01* Downloaded from www.Manualslib.com manuals search engine...
Seite 136
ABD'de ve/veya diğer ülkelerde ticari markaları veya tescilli ticari markalarıdır. Bu belgede, marka ve adların sahiplerine ya da ürünlerine atıfta bulunmak için başka ticari marka ve ticari adlar kullanılabilir. Dell Inc. kendine ait olanların dışındaki ticari markalar ve ticari isimlerle ilgili hiçbir mülkiyet hakkı olmadığını beyan eder.
Birleşik ağ anahtarı ile ilgili değiştirme işlemi içindir. Birleşik ağ anahtarı, SAN bağlantısı için Dell M1000e Blade Server Enclosure'ın B1/B2 G/Ç ve C1/C2 G/Ç yuvalarında çalışacak şekilde tasarlanmıştır. Blade Server Enclosure Donanım Sahibi Kılavuzu'ndaki yükleme gereksinimlerine uyduğunuzdan emin olun.
Seite 138
• Gerektiğinde SFP alıcı vericileri ve uyumlu fiber kablolar. anahtar modülü, ikiz koaksiyel bakır kabloyla da kullanılabilir. Bu modülün harici bağlantı noktalarında yalnızca Dell'in onayladığı SFP'leri kullanın. • Birleşik ağ anahtarı yapılandırmasını yedeklemek için bir FTP sunucusuna erişim. •...
Seite 139
2. CMC uygulamasının Ayarlar sekmesini açın. 3. IP Adresi, Alt Ağ Maskesi ve Ağ Geçidi alanlarına yeni bilgileri girin ve Uygula'yı tıklatın. 4. DHCP'yi etkinleştirmek için DHCP Etkin'i seçip Uygula'yı tıklatın. Dell M8428-k Başlangıç Kılavuzu 137 / 160 MHWKY Downloaded from www.Manualslib.com...
Seite 140
CMC Ayarlar Sekmesi Ek ayrıntılar için CMC GUI uygulamasının belgelerine bakın. IP adresini ayarlamak için Dell M8428-k CLI'yi kullanma anahtar modülü modülünün CLI'sini kullanarak modülle ilgili IP adresini değiştirmek için aşağıdaki görevleri kullanın. İlk birkaç adımını izleyerek, anahtar modülü ile bir Blade Server Enclosure yönetim iş istasyonu arasında, anahtar modülü...
Seite 141
1. Anahtarda oturum açın. 2. Aşağıdaki komutu girin: cmsh 3. Komut kabuğunda, aşağıdaki komutu girin: enable 4. Aşağıdaki komutu girin: conf t Dell M8428-k Başlangıç Kılavuzu 139 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 142
Gerekli tüm SFP alıcı vericilerine ve diğer optik ya da etkin ikiz koaksiyel bakır kablolara sahip olduğunuzdan emin olun. a. Kullanılacak bağlantı noktalarındaki toz önleme kapaklarını çıkarın. b. Gerekirse, SFP'den uç kapaklarını çıkarın. Dell M8428-k Ba ş langıç Kılavuzu 140 / 160 MHWKY Downloaded from www.Manualslib.com...
Seite 143
Geri kalan alıcı vericiler için gereken adımları tekrarlayın. 4. Tüm bileşenlerin işanahtar modülülediğini doğrulamak için LED'leri kontrol edin. LED yanma modelleriyle ilgili bilgi için Dell M8428-k Donanım Başvuru Kılavuzu'nda "Birleşik ağ anahtarı Çalıştırma" bölümüne bakın. 5. İş istasyonundan switchShow komutunu yazarak Birleşik ağ anahtarı modülünün doğru şekilde çalıştığını...
Seite 144
Oturum açma adı: admin Parola: password 2. Anahtarı devre dışı bırakmak için aşağıdaki komutu girin. switchDisable 3. Anahtar yapılandırmasını yedekleyin. Ayrıntılar için bkz. Yapılandırmayı yedekleme, sayfa 144. Dell M8428-k Ba ş langıç Kılavuzu 142 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 145
4. Ağ Sistemi Ağacı'ndan Birleşik ağ anahtarı öğesini seçin. Seçilen anahtar modülü, Anahtar Görünümü'nde görünür. 5. Tarayıcı tabanlı GUI'yi Yönet görev kutusunda Anahtar Yönetimi düğmesini tıklatın. Anahtar Yönetimi penceresi açılır. Dell M8428-k Başlangıç Kılavuzu 143 / 160 MHWKY Downloaded from www.Manualslib.com...
Seite 146
1. Anahtar modülünde bir Telnet veya SSH oturumu açın. 2. Anahtar modülünün temel yapılandırmasını karşıya yüklemek için aşağıdaki komutu girin: configUpload Bundan sonra bir dizi istemle karşılaşırsınız. Dell M8428-k Ba ş langıç Kılavuzu 144 / 160 MHWKY Downloaded from www.Manualslib.com...
Seite 147
Parolayı girdiğinizde kopyalama yordamı başlar. Bu komutlar anahtar modülü yapılandırmalarını sunucuya yükler, böylece gerektiğinde yedek anahtar modülüne olarak indirilebilir. Dell, tüm yapılandırmanın bir yedek anahtar modülüne indirilebilmesini sağlamak üzere yapılandırmanın düzenli olarak yedeklenmesini önerir. Dell M8428-k Başlangıç Kılavuzu 145 / 160...
Seite 148
Dell M8428-k Ba ş langıç Kılavuzu 146 / 160 MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 149
Dell M8428-k -מדריך תחילת עבודה ל 160 061 מתוך MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 150
.לאחר הזנת הסיסמה, הליך ההעתקה מתחיל .פקודות אלו מעלות את תצורת מודול המתג לשרת, והופכות אותה לזמינה להורדה למודול מתג חלופי, במידת הצורך ממליצה לגבות את התצורה באופן קבוע, כדי להבטיח שהתצורה המלאה תהיה זמינה להורדה עבורDell חברת .מודול מתג חלופי...
Seite 151
:כניסה password :סיסמה :הזן את הפקודה הבאה כדי לנטרל מצב מארג מלא switchDisable 159 גיבוי התצורה בעמוד גבה את תצורות המתג. לפרטים, ראה Dell M8428-k -מדריך תחילת עבודה ל 160 851 מתוך MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 152
. N_Port עדF_Port מוחק את מיפוי , רק קבוצת משנה מוגבלת של פקודות מערכת ההפעלה זמינה וכלNPIV לאחר אפשור מתג הרשת המתכנסת במצב .בקשות השירות הקשורות למארג מועברות למתגי המארג 160 751 מתוך Dell M8428-k -מדריך תחילת עבודה ל MHWKY Downloaded from www.Manualslib.com...
Seite 153
, על-ידי הקלדת הפקודהFTP גבה את תצורת מודול המתג לשרת פקודה זו טוענת את תצורת מתג הרשת המתכנסת לשרת, והופכת אותה לזמינה להורדה למתג רשת מתכנסת ממליצה לגבות את התצורה באופן קבוע, כדי להבטיח שהתצורה המלאה תהיהDell חלופי במידת הצורך. חברת .זמינה להורדה עבור מודול מתג חלופי...
Seite 154
- וb , a חזור על שלבים הערה . Dell המאושרים על-ידיSFPs -ביציאות האופטיות החיצוניות של מודול זה השתמש רק ב .חבר את הכבלים למקמ"שים המקמ"שים מסומנים כדי להבטיח כיוון כהלכה. אם מקמ"ש אינו מותקן בקלות, ודא שהוא מכוון כהלכה ושכיסויי...
Seite 155
. CMC - כמו הEthernet נוספת. תחנת העבודה לניהול חייבת להיות באותה רשת משנה הערה .ודא שלא מבוצעים שינויים במודול המתג מכל חיבור אחר, עד להשלמת קביעת התצורה Dell M8428-k -מדריך תחילת עבודה ל 160 451 מתוך MHWKY Downloaded from www.Manualslib.com...
Seite 156
. השתמש בשלבים הבאים כדי לקבוע אתCEE כדי לגשת למעטפת הפקודותcmsh כניסה למתג, השתמש בפקודה . CEE -התצורה של יציאות ה .בצע כניסה למתג :הזן את הפקודה הבאה cmsh 160 351 מתוך Dell M8428-k -מדריך תחילת עבודה ל MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 157
. CMC -לפרטים נוספים, עיין בתיעוד עבור ממשק המשתמש הגרפי של ה IP - להגדרת כתובת הDell M8428-k - של הCLI -שימוש ב ( שלCLI) במודול המתג באמצעות ממשק שורת הפקודהIP -השתמש במשימות הבאות כדי לשנות את כתובת ה...
Seite 158
Gateway - )מסיכת רשת משנה( וSubnet Mask , (IP )כתובתIP Address הזן את המידע החדש בשדות .( )החלApply )שער( כנדרש ולאחר מכן לחץ על .()החל Apply )מאופשר( ולחץ עלDHCP Enabled , בחרDHCP כדי לאפשר 160 151 מתוך Dell M8428-k -מדריך תחילת עבודה ל MHWKY Downloaded from www.Manualslib.com manuals search engine...
Seite 159
וכבלי סיבים אופטיים, כנדרש. ניתן להשתמש במודול המתג גם עם כבלי נחושת מסוגSFP מקמ"שי • הערה . Dell המאושרים על-ידיSFPs -ביציאות החיצוניות של מודול זה השתמש רק ב . לגיבוי התצורה של ה- מתג רשת מתכנסת FTP גישה לשרת...
Seite 160
במהירות. לקבלת הוראות מפורטות על התקנה וקביעת תצורה, עיין במדריך העזרDell M8428-k את התצורה של . Dell M8424-k לחומרה של הערה M8428-k 10GbEE- נקרא מתג רשת מתכנסת או מודול מתג. הוא נקרא גםDell M8428-k ,לאורך מסמך זה .FCOE/8Gb FC SW הוצאה מאריזה והתקנה של מתג רשת מתכנסת...
Seite 161
. Dell Inc -חל איסור מוחלט על העתקה מכל סוג של חומרים אלה ללא הרשאה בכתב מ , PowerEdge , Latitude , OptiPlex , Dimension , Dell Precision , Inspiron , DELL , הלוגוDell :סימנים מסחריים שבשימוש בטקסט זה הםCeleron - וPentium , Intel ; Dell Inc הם סימנים מסחריים שלDell OpenManage - וPowerConnect , PowerApp , PowerVault -...
Seite 162
MHWKY 2010 ,51 אוקטובר Dell M8428-k מדריך תחילת עבודה 53-1002029-01 53-1002029-01 Downloaded from www.Manualslib.com manuals search engine...
Seite 163
Downloaded from www.Manualslib.com manuals search engine...
Seite 164
Printed in the U.S.A. Imprimé aux U.S.A. Gedruckt in den USA. Dicetak di A.S. Impresso nos EUA. Impreso en los EE.UU. A.B.D.'de basýlmýþtýr. w w w. d e l l . c o m | s u p p o r t . d e l l . c o m Downloaded from www.Manualslib.com manuals search engine...
Seite 165
Downloaded from www.Manualslib.com manuals search engine...
Seite 166
Printed in China Imprimé en Chine Gedruckt in China Dicetak di China Impresso na China Impreso en China Çin'de basýlmýþtýr Printed on Recycled Paper w w w. d e l l . c o m | s u p p o r t . d e l l . c o m Downloaded from www.Manualslib.com manuals search engine...
Seite 167
Downloaded from www.Manualslib.com manuals search engine...
Seite 168
Printed in Malaysia Imprimé en Malaisie Gedruckt in Malaysia Dicetak di Malaysia Impresso na Malásia Impreso en Malasia Malezya'da basýlmýþtýr w w w. d e l l . c o m | s u p p o r t . d e l l . c o m Downloaded from www.Manualslib.com manuals search engine...
Seite 169
Downloaded from www.Manualslib.com manuals search engine...
Seite 170
Printed in Brazil Imprimé au Brésil Gedruckt in Brasilien Dicetak di Brasil Impresso no Brasil Impreso en Brasil Brezilya'da basýlmýþtýr w w w. d e l l . c o m | s u p p o r t . d e l l . c o m Downloaded from www.Manualslib.com manuals search engine...
Seite 171
Downloaded from www.Manualslib.com manuals search engine...
Seite 172
Printed in Poland Imprimé en Pologne Gedruckt in Polen Dicetak di Polandia Impresso na Polônia Impreso en Polonia Polonya’da basýlmýþtýr w w w. d e l l . c o m | s u p p o r t . d e l l . c o m Downloaded from www.Manualslib.com manuals search engine...