9
Accuracy Check
The accuracy of the laser beam should be checked regularly. This requires a free measuring length
of 10 m. The check takes place in two steps.
Step 1
•
Position the CrossLiner 4 as shown in the diagram to
the right.
•
Switch on the horizontal laser line using the "H" switch.
•
Mark point A on the laser line.
•
Rotate the CrossLiner 4 through 180° and mark point B
on the laser line.
Step 2
•
Position the CrossLiner 4 opposite as shown in the
diagram to the right.
•
Align the CrossLiner 4 with marking B.
•
Rotate the CrossLiner 4 through 180° .
•
Measure the vertical distance H between marking A and
laser line C*.
•
If the measured distance H between marking A and
laser line C* is < 6 mm, the CrossLiner 4 is within the
tolerance range.
* The laser line C may be above or below marking A.
Note: If the vertical measured distance H between marking A and the laser line C is outside the
tolerance range, the CrossLiner 4 must be examined by an authorised customer service agent or
by NEDO.
Operating Instructions CrossLiner 4
19
A
B
~0,5 m
10 m
EN