INSTALLATION
Alternative installation methods
14.7 Fitting appliance cover for water installation on
finished walls
4
3
2
1
1 Back panel guides
2 Screw
3 Cover guides with sealing lips on the pipe side
4 Pipe knock-out
f Cleanly saw and break out the pipe knock-outs in the appli-
f
ance cover. If necessary, use a file.
f When installing the connection pipes without an offset, break
f
off the sealing lips on the cover guides.
f Click the cover guides into place in the knock-outs.
f
f Position the back panel guides on the pipes. Push them to-
f
gether. Then push the guides against the back panel as far
they will go.
f Secure the lower back panel section with a screw.
f
www.stiebel-eltron.com
Note
Use the cover guides with sealing lips if the connection
pipes are slightly offset. In this case, the back panel
guides are not fitted.
14.8 Lower back panel section installation with
threaded fittings on finished walls
3
1
1 Lower back panel section
2 Connection piece in the standard delivery
3 Screw
If using threaded fittings on finished walls, the lower back panel
section can also be installed after fitting the taps. To do this, carry
out the following steps:
f Cut open the lower back panel section.
f
f Fit the lower back panel section by bending it out at the sides
f
and guiding it over the pipes.
DHE Connect | DHE Touch |