Herunterladen Inhalt Inhalt Diese Seite drucken

Configuration - ECOLAB Versatronic Kurz- Betriebsanleitung

Modulares mehrkanalmessgerät
Vorschau ausblenden Andere Handbücher für Versatronic:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Device menu
Configuration item
KT X Sa biocide 2 T1
(only at C1) *
KT X Sa biocide 2 T2
(only at C1) *
Configuration item
KT X desalination
monitoring y / n
KT X time desalination
monitoring
KT X Signal monitor. y / n
KT X time Signal monitor.
KT Cal.timer X j / n
KT X Calibr.interv.
KT X Source Temp.
KT X Temp. connection type 2-wire
* = see
Ä Chapter 5.2 'Material code' on page 16
10.4

Configuration

See operating instructions 417102269, chapter 'configuration' .
417102279 Rev. 2-08.2020
Selection/configuration
Hours minutes seconds
(Hh: mm: ss)
Area: 0-23: 0-59: 0-59
Hours minutes seconds
(Hh: mm: ss)
Area: 0-23: 0-59: 0-59
Selection/
configuration
Explanation
Inactive
Activation of desalination
active
monitoring
(If the section input is not
completed after the start of the
desalination via an adjustable
time out, the display shows
"flush alarm".)
Number field
Setting the time for the
Area: - 999 to 999 s
desalination monitoring
Inactive
Activation signal monitoring
active
(At the time when a biocide
dosage is pending, when the
enable signal is not given, wait
for a period when the
adjustments are possible, if
the signal is given. If no enable
signal is given after the time
period lapses, an "enable
alarm" signal is output.)
Number field
Setting the time for signal
Area: - 999 to 999 s
monitoring
Inactive
Activation Calibration
active
0-9999 days
Determining the calibration
interval
The calibration interval is the
time after which a Calibration
reminder is displayed on the
display (see
9.1.3 'Display elements'
on page 38). After performing
a calibration, the Calibration
Reminder is deleted on the
display.
*IN4 temperature input
Determining the source for the
1
temperature display and for
* IN5 temperature input
the temperature compensation
2
of the respective channel.
...
With this selection, it is
IN11 Universal input. 2
possible to use the
uncomp.*IN11
temperature signal of another
Universal input 2
channel for the display and
comp.
temperature compensation of
IN12 Universal input. 3
this channel.
uncomp.
* IN12 Universal input.
3 comp.
* = please select only the marked
points!
Connection type of the
temperature sensor
3-wire
48
Explanation
Dosage biocide 2
time 1
Saturday
Dosage biocide 2
time 2
Saturday
Default
Inactive
0 sec
Inactive
0 sec
Inactive
10 days
Ä Chapter
Channel 1: IN4
Channel 2: IN5
Channel 3: IN11
comp.
Channel 4: IN12
comp.
3-wire
Default
00:00:00
00:00:00

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis