1. Introduction
The MICROSTIRRER magnetic stirrer is a small, simple and effective stirrer. Thanks to the white cover surface it is specially
designed for microtitrations, and it is extremely useful where reliable and small instrument is needed. The stirrer stays cold
even after several days of continuous use. This feature makes it highly appreciated in microbiology and biochemistry.
The technopolymer structure is studied and tested in order to give to the instrument an excellent resistance to the attack of
chemical agents and to corrosion in general.
NOTE: it's important to choose the most suitable magnetic stirring bar related to the quantity and the liquid to be stirred as
well as to the type of the beaker. The magnetic stirring bar that satisfies most of the application is A00001056 (6x35mm).
2. Assembly and installation
Upon receipt and after having removed the packaging, please check the integrity of the instrument. The box includes:
•
Magnetic stirrer MICROSTIRRER
•
Plug for power supply
2.1 Electrical connection
After having unpacked the instrument, place the unit on the laboratory bench.
Before connecting the instrument to the power supply, make sure that the values on the rating plate correspond to those of
the power supply. Connect the unit to the power supply using the transformer supplied.
Ensure that the socket and the relative cut-off device conform to current safety norms and easy to reach.
2.2 Start-up
Rotate the speed knob completely to the left. Place the flasks containing the sample and a suitable magnetic stirring bar on
the stirring plate. Then, set the speed by turning the speed knob.
2.3 Information about construction materials
Structure
Aluminum
3. Operating controls
Turn the stirring speed knob on the front panel in order to start the stirring function.
It is possible to select speeds between 0 and 1100 rpm.
When the led is lighted it means that the stirring is on
4. Maintenance
No routine or extraordinary maintenance is necessary apart from periodically cleaning the unit as described in this manual.
In compliance with the product guarantee law, repairs to our units must be carried out in our factory, unless previously
agreed otherwise with local distributors. The instrument must be transported in its original packaging and any indications
present on the original packaging must be followed (e.g. palletized).
It is the responsibility of the user, to properly decontaminate the unit in case of hazardous substances remaining on the
surface or interior of the device. If in doubt about the compatibility of a cleaning or decontamination product, contact the
manufacturer or distributor.
4.1 Cleaning
Disconnect the unit from the power supply and use a cloth dampened with an non-inflammable non-aggressive detergent.
•
Switching VELP 100-240V/12V without plug
•
Instruction manual
Frontal panel label
PET
5
EN
Feet
MQ/MVQ