Profilux units for 220 - 240 V:
Halogen tube with bayonet mount. Lightly press tube
(20) inwards and, keeping it depressed, turn through
º revolution counterclockwise.
Profilux units for 110 - 130 V:
Remove Pyrex globe (25); see item 15. Withdraw
halogen tube.
Remove tube and replace with new one, taking care
not to touch the new tube with your fingers. Follow
manufacturer's instructions.
Before changing the flash tube, switch the unit off,
pull the power plug and wait for about one hour to
allow the capacitors to discharge. Then carefully
withdraw flash tube (19) and replace it with a new one.
Make sure that the tube is firmly seated all the way
down in the base, the triggering contact (21)
surrounding the tube on either side.
13. Fuses
To change fuses, switch the unit off and pull the
power plug. Fuse drawer (9): Push the fuse drawer
(9) out towards the front with the aid of small
screwdriver placed behind the upper part of the
drawer. The fuse is located at the rear, a spare fuse
at the front of the drawer. Always replace the blown
fuse by one of identical rating:
Profilux - 200/400/600 220 - 240 V = T 3.15 A
Profilux - 200/400/600 110 - 130 V = T 4 A
Downloaded from
www.Manualslib.com
manuals search engine
14. Thermal protection
The units have a thermal circuit breaker that responds
to very high ambient temperature and heavy-duty
use.
When the circuit breaker acts, the flash will not fire
any more, and the modeling light goes out. The LED
(15) above the open-flash button (14) is OFF, while all
other LEDs stay lit. Once it has cooled down
sufficiently, the unit switches on automatically. Under
normal operating conditions, the built-in fan provides
sufficient cooling.
15. Pyrex globe
Profilux units for 110 - 130 V are factory-equipped
with a protective Pyrex globe (25). To remove the
globe, press the two wire springs (26) inwards with a
pointed object so that they clear the screws (27), and
lift them out. After changing the flash tube, replace
the globe (25) and press the two springs (26) back
underneath the screws.
16. Care and maintenance
At the end of the shoot, pull the power plug. Units that
are used regularly should be serviced by Multiblitz
once a year.
The flash unit should be carefully protected from
water splashes.