SGP/1
26
Installation
WARNING
NOTICE
Downloaded from
www.Manualslib.com
Mounting the wire hook
1. Mount the wire hook
ing position.
2. Mount the wire hook
7) condition.
3. After mounting with the wire hook opened closed the wire hook again
(see
Fig.
7).
Fig. 5: Wire accommodation with hook
Fig. 6: Wire hook closed
4.2 Electrical installation
Destruction of parts of equipment and loss of regulation control
` All lines for connecting the wire-actuated encoder must be shielded.
` Never wire or disconnect electrical connections while they are live.
` Perform wiring work in the de-energized state only.
` Use strands with suitable ferrules.
` Wiring to the screen and ground (0 V) must be secured to a good
point. Ensure that the connection of the screen and earth is made to a
large surface area with a sound connection to minimise impedance.
` Check all lines and plug connections before switching on the device.
` Switch on operating voltage together with the downstream electronic
unit (e. g., control unit).
Basically, all connections are protected against external interference.
Choose a place of operation that excludes inductive or capacitive interfer-
ence influences on the wire-actuated encoder. When mounting the system
keep a maximum possible distance from lines loaded with interference. If
necessary, provide additional installations including screening shields or
metallized housings.
SGP/1 · Date 03.07.2017 · Art. No. 84050 · Mod. status 206/17
manuals search engine
(Fig.
5,
Fig.
6,
Fig.
7):
or wire, respectively to the intended fasten-
1
Fig.
in the closed (see
1
1
Fig. 7: Wire hook opened
English
6) or opened (see
Fig.
Wire hook
1