Transport
CAUTION
Risk of injury, risk of damage
Be aware of the weight of the device during
transportation.
1. When transporting in vehicles, secure
the device against slipping and tipping
over according to the applicable guide-
lines.
Storage
CAUTION
Risk of injury and damage
Be aware of the weight of the device during
storage.
Care and service
WARNING
Risk of injury
The device may start up unexpectedly.
Be sure to pull the mains plug out of the
socket before you start working on the de-
vice.
1. Wash dirty pads at a maximum of 60 °C.
2. Clean the casing of the device with a
damp cloth and then rub dry.
3. Check the mains cable for damage.
Troubleshooting guide
WARNING
Risk of injury
The device may start up unexpectedly.
Be sure to pull the mains plug out of the
socket before you start working on the de-
vice.
In the event of malfunctions that cannot be
remedied using the following information,
please contact customer service.
Unsatisfactory cleaning results
Replace the soiled pad and wash at a
maximum of 60 °C.
Replace a worn brush/pad.
Check the suitability of the detergent
used for the application.
Check the suitability of the brush/pad
used for the application.
The device vibrates strongly
Check for central positioning of the pad
on the pad drive board.
Check the attachment of the brush/pad.
The pad does not rotate
Check if foreign objects are blocking the
pad drive board. Remove any foreign
objects if necessary.
Plug the mains plug into the socket.
The warranty conditions issued by our relevant
sales company apply in all countries. We shall
remedy possible malfunctions on your appli-
ance within the warranty period free of cost,
provided that a material or manufacturing de-
fect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt)
or the next authorised customer service site.
(See overleaf for the address)
Technical data
Device performance data
Voltage
Phase
Frequency
Connection output
Degree of protection
Pad
Pad diameter
Pad speed
Ambient conditions
Permissible temperature
range
Dimensions and weights
Length
Width
Height
Weight without accessories kg
Determined values in acc. with EN
60335-2-72
Overall vibration value
Uncertainty K
Sound pressure level L
Uncertainty K
Sound power level L
K uncertainty
Subject to technical modifications.
English
Warranty
V
~
Hz
W
mm
1/min 0...450
°C
mm
mm
mm
2
m/s
dB(A) 0,2
dB(A) 68,6
pA
dB(A) 1
pA
+
dB(A) 77,2
WA
WA
220-
230
1
50-60
150
IPX4
160/200
+5...
+40
330
140
300
5,4
<2,5
11