Herunterladen Diese Seite drucken

Electrical Connection - Pelgrim IDK650 Anleitung

Vorschau ausblenden Andere Handbücher für IDK650:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

installation
122

Electrical connection

For the connection, use an approved cable, in accordance with the regulations.
The cable casing should be of rubber.
There is a label on the underside of the appliance with the wiring diagrams. The
connection terminals are accessible once you have opened the junction box on
the underneath. The junction box cover can be opened with a screwdriver.
If you want to make a fixed connection, make sure that a multi-polar switch with
a contact separation of at least 3 mm is fitted in the supply line.
Power setting table
Type of hob
Induction
Eelctrical connection
230 V - 50 Hz
Maximum power cooking zones
Front left
Rear left
Rear right
Front right
power connection
L1
L2
Total power connection
IDK650
x
x
3000 W
2000 W
2800 W
2800 W
3000 W
2800 W
5800 W
installation
123
The appliance can be connected in the following ways:
1 phase connection (1 1N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c.
Install connecting bridges between connection points 1-2 and 4-5.
Your group must be protected by a fuse of at least 32 A. The connecting power
cable must have a minimum core cross section of 6 mm
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz):
The voltage between live and neutral is 230 V a.c. There may be a voltage of
0 V between the phases if they are connected to the same phase in the meter
cupboard but also 400 V if they are connected to 2 different phases. Your
groups must be fused with at least 16 A (2x). The connecting power cable must
have a minimum core cross section of 2,5 mm
2
.
generator right
generator left
2
.
generator right
generator left

Werbung

loading