HP StorageWorks
Modular Smart Array 1510i
controller
installation instructions
© Copyright 2005-2006 Hewlett-Packard Development Company, L.P.
Second edition February 2006
Product names mentioned herein may be trademarks of their respective
companies as reflected by an associated footnote.
Information in this document is subject to change without notice.
Printed in the US.
www.hp.com
*383076-022*
383076-022
1
2
2
1
Downloaded from
www.Manualslib.com
1
2
manuals search engine
English
About this document
This document details procedures for installing a redundant controller in an HP
StorageWorks Modular Smart Array 1510i (MSA1510i.)
Before you begin
Read the following cautions and notes.
CAUTION:
Parts can be damaged by electrostatic discharge. Use proper
anti-static protection. See documentation shipped with your system for
additional information.
NOTE:
You can hot-add this redundant component to the MSA1510i.
Removing power from the device is not required.
Installing the redundant controller
Step 1: Remove the controller blank
1
Press the controller blank thumb latch and pull the latch handle out
[Figure 1 (1)].
1.
Pull the blank straight out of the chassis
Step 2: Install the redundant controller
1.
Insert the redundant controller into the chassis
2.
Push the controller in as far as it will go, and then press the latch handle
inward, until it is flush against the front panel
Confirming the firmware version
If the firmware versions on the two controllers are mismatched, the following
LCD message may be displayed:
07. CLONE FIRMWARE? '<' = NO, '>' = YES
To select YES, press the left navigation button on the controller.
To select NO, press the right navigation button.
HP recommends selecting YES to copy the firmware from the active controller
to this new redundant controller. If NO is selected, the redundant controller is
disabled and the storage system runs in a non-redundant mode.
Verifying controller status
Verify that the controller heartbeat LED (1) is on or blinking.
Verify that the controller fault LED (2) is off.
15173
Additional information
See the HP StorageWorks MSA1510i maintenance and service guide
or other MSA1510i-related documents on the MSA1510i web site:
http://h18006.www1.hp.com/products/storageworks/msa1510i
15174
[Figure 1 (2)]
.
[Figure 2 (1)]
.
[Figure 2 (2)]
.
1
2
15192
.

Werbung

loading

Inhaltszusammenfassung für HP StorageWorks Modular Smart Array 1510i

  • Seite 1 HP StorageWorks English About this document Modular Smart Array 1510i This document details procedures for installing a redundant controller in an HP controller StorageWorks Modular Smart Array 1510i (MSA1510i.) Before you begin installation instructions Read the following cautions and notes.
  • Seite 2 Controller. Um NO auszuwählen, drücken Sie die rechte Navigationstaste. Comprobación del estado del controlador HP empfiehlt die Auswahl von YES zum Kopieren der Firmware vom aktiven • Compruebe que el LED de latencia del controlador (1) está encendido o Controller auf den neuen redundanten Controller. Bei Auswahl von NO wird der parpadea.
  • Seite 3 Pour sélectionner YES, appuyez sur le bouton de navigation de gauche sur le contrôleur. HP consiglia di selezionare SÌ per copiare il firmware dal controller attivo al Pour sélectionner NO, appuyez sur le bouton de navigation de droite. nuovo controller ridondante. Se si seleziona NO, il controller ridondante viene disattivato e il sistema di memorizzazione viene eseguito in modalità...
  • Seite 4 Als u YES wilt selecteren, drukt u op de linkernavigatieknop op de controller. Als u NO wilt selecteren, drukt u op de rechternavigatieknop. HP raadt aan YES te selecteren om de firmware te kopiëren van de actieve controller naar deze nieuwe redundante controller. Als u NO selecteert, wordt de redundante controller uitgeschakeld en werkt het Storage System in een niet-redundante modus.

Diese Anleitung auch für:

Storageworks msa1510i