The Manufacturer declines all responsibility for failure to comply with the safety
regulations.
FUMES DISCHARGE
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this version, air passes through zeolite-carbon filters to
be purified and recycled in the environment. Make sure
the zeolite-carbon filters are installed in the hood, other-
wise, apply them as indicated in the assembly instructions.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualified
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case,
follow the specific steps provided for the required installation.

OPERATION

WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct fumes
and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours
and odours. By means of the Timer function, it is possible to set auto switch-off
function which will allow the hood to turn off automatically after 15 minutes of
operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity consump-
tion.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The zeolite-carbon filters must be reactivated every 18 months and replaced
every 3 years.
For further details see the "MAINTENANCE" chap.
ROTARY SWITCH - CONTROLS
(DAMA - LOOP - SOFFIO - SOPHIE)
OFF
OFF
I I I
PUSH
ELECTRONIC PUSHBUTTON PANEL
(MATERIA - VETRA)
USING THE RADIO CONTROL
PUSH
and with the hood electronics.
The maximum operating distance is 5 metres, that may vary according to
the presence of electromagnetic interferences.
Radio control operated at 433.92MHz.
The radio control consists of two parts:
- the receiver built into the hood;
- the transmitter shown here in the figure.
26
Motor OFF
I
speed 1 (green light)
I I
speed 2 (blu light)
speed 3 (violet light)
speed 4 (red light). It is activated by pressing the button
2 seconds. After a few minutes it comes back ti speed 3.
Pressing for a second:
On / off light
TIMER (can only be activated by remote control)
(flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
The TIMER key
is pressed again or motor OFF.
FILTER ALARM (motor OFF)
Anti-grease filter maintenance after approximately 30 hours of op-
eration.
Press
for 4 seconds to reset.
Motor ON/OFF
Upon start-up, the speed is that stored at the previous operation.
Increase speed from 1 to 4
Speed 4 is only active for a few
minutes, then speed 3 activa-
tes.
Reduce speed from 4 to 1
Light on/off
TIMER (red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The TIMER key ( ) is pressed again.
- The ON/OFF key ( ) is pressed.
FILTER ALARM (red LED steady on with ( ) off)
Anti-grease filter maintenance after approximately 30 hours of op-
eration.
Press ( ) the meter for 3 seconds to reset.
WARNINGS!:
Place the hood away from sources of electromagnetic waves (e.g.
microwave ovens), which could interfere with the radio control
for
The speeds are indicated by the
LEDs on the keys:
Speed 1
Speed 2
Speed 3
Speed 4