12.2
Sterilisation capacity
Bitron Premium 60 W
Bitron Premium
120 W
Bitron Premium
180 W
12 mWs/cm²
Required energy for deactivating Chlorella vulgaris (single-cell green algae)
5.5 mWs/cm²
Required energy for deactivating Pseudomonas aeruginosa
12.3
Water values
Type
pH value
Hardness
Free chlorine
Chloride content
Overall dry residue
Temperature
13
Symbols on the unit
Flow rate
16500 l/h
18000 l/h
30000 l/h
19800 l/h
38700 l/h
50000 l/h
Complete protection against contact, dust-tight, protected from continuous immersion in water
to a depth of 0.1 m.
Protection against touching dangerous components with objects up to 1 mm diameter.
Protection against splash water.
Dangerous UVC radiation.
Protect from direct sun radiation.
Completely drain the unit for temperatures below zero.
Do not dispose of with household waste.
Read and adhere to the instructions for use.
UVC power
Energy required for sterilisation
60 W
60 W
60 W
120 W
60 W
60 W
120 W
60 W
120 W
180 W
Fresh water
7.2 ... 7.6
8 ... 15 DH
<0.3 mg/l
<250 mg/l
<50 mg/l
+4 ... +35°C
- EN -
12 mWs/cm²
12 mWs/cm²
7.2 mWs/cm²
12 mWs/cm²
12 mWs/cm²
9.2 mWs/cm²
12 mWs/cm²
4.7 mWs/cm²
9.2 mWs/cm²
12 mWs/cm²
Pool water
7.2 ... 7.6
8 ... 15 DH
0.3 ... 0.6 mg/l
<200 mg/l
<50 mg/l
+4 ... +30°C
47