Herunterladen Inhalt Inhalt Diese Seite drucken

Before Starting The Equipment; Operation - HERKULES SE 3000 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

5. Before starting the equipment

5.1 Assembly
Assemble the foot, wheels and push bar as
shown in Figures 6-9.
Assemble all parts before filling in fuel and oil
in order to prevent the fluids from leaking out.
To mount the wheels, first slide the axle (15)
through the mountings on the bottom of the
generator and fit the wheels (14) as shown on
Figure 7. When fitting the push bar (18) check
that the angled side (Fig. 9/Item E) is pointing
outwards to ensure that the swing up function
works properly.
5.2 Electrical safety:
Electric supply cables and connected equip-
ment must be in perfect condition.
The generator is to be operated only with
equipment whose voltage specifications con-
form with the generator's output voltage.
Never connect the generator to the power
supply (socket-outlet).
Keep the cable length to the consumer as
short as possible.
5.3 Environmental protection
Dispose of soiled maintenance material and
operating materials at the appropriate collec-
tion point.
Recycle packaging material, metal and plas-
tics.
5.4 Connecting to earth
The housing is allowed to be connected to earth
in order to discharge static electricity. To do this,
connect one end of a cable to the earth connec-
tion on the generator (Fig. 4) and the other end to
an external earth (for example an earthing rod).
Anl_SE_3000_SPK7.indb 20
Anl_SE_3000_SPK7.indb 20
GB

6. Operation

Important! You must fi ll up with engine oil and
fuel before you can start the engine.
Check the fuel level and top it up if necessary
Make sure that the generator has sufficient
ventilation
Make sure that the ignition cable is secured to
the spark plug
Inspect the immediate vicinity of the gene-
rator
Disconnect any electrical equipment which
may already be connected to the generator
6.1 Starting the engine
Open the petrol cock (13) by turning it down
Move the ON/OFF switch (10) to position
„ON" with the key.
Move the choke lever (11) to position IØI.
Start the engine with the reversing starter (12)
by pulling the handle forcefully. If the engine
does not start, pull the handle again.
Push the choke lever (11) back again after
the engine has started.
Important!
When starting with the reserve starter, the motor
may recoil suddenly as it starts up, resulting in
hand injuries. Wear protective gloves when star-
ting the equipment.
6.2 Connecting consumers to the generator
Set the selector switch (Fig. 1/Item 25) to the
left to use 230V~ sockets. Important: These
sockets may be loaded continuously (S1) with
1500W and temporarily (S2) for a maximum
of 5 minutes with 1800W.
Set the selector switch (Fig. 1/Item 25) to the
right to activate the 400V 3~ socket. Impor-
tant: This socket may be loaded continuously
(S1) with 2600W and temporarily (S2) for a
maximum of 5min. with 2800W.
The generator is suitable for 230 V~ and 400
V 3~ alternating voltage appliances.
Do not connect the generator to the domestic
power network as this may result in damage
to the generator itself or to other electrical
appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power con-
sumption when used in diffi cult conditions.
- 20 -
11.06.2018 09:05:07
11.06.2018 09:05:07

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis