Installation
EN
7.2

Installation Conditions

EN
EN
Inadmissible mechanical load!
EN
Protect the device from mechanical load.
EN
EN
EN
EN
Internal wiring
EN
EN
EN
7.3

Mounting and Operating Position

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
14
Downloaded from
www.Manualslib.com
This device is suitable for outdoor and indoor use.
If the explosion protected equipment is exposed to the weather, it is advisable
to provide a protective cover or wall.
Use only wires which can be used for the corresponding temperature.
Incorrectly performed installation!
Risk of severe injuries.
Observe the thread sizes for the cable entries specified in the equipment
documentation.
The connection line must comply with the relevant regulations and must
have the required cross-section. The diameter must be identical to the data
on the bushing.
Ensure that the maximum permissible conductor temperatures are not
exceeded by selecting suitable wires and means of running them.
The permissible ambient temperature at the intrinsically safe built-in
devices and components must not be exceeded.
The switchgear combination must only be installed in a dry and clean
environment.
Installation in dust Ex areas!
The control panel 8265/5*-*** must not be used in areas where highly
charge-generating processes, machine friction and separation processes,
electron spraying (e.g. around electrostatic coating systems) and
pneumatically conveyed dust occur.
Increased temperature due to connection cable!
If the selected connection cable causes a temperature of more than 70 °C
at the cable entries, the cable entries must be designed for the
corresponding temperature.
Fasten the device to the attachment holes provided for this purpose using
suitable screws and accessories (see dimensional drawings).
Observe the weight of the enclosure!
If necessary, use suitable auxiliary tools for transport.
When mounting the component, ensure presence of a flat surface.
Ex d Enclosures Made of Light
Metal "Flameproof Encapsulation"
manuals search engine
WARNING
WARNING
WARNING
WARNING
143457 / 826560300010
2014-10-13·BA00·III·en·07