Operating Instructions SATAjet 100 B F (RP / HVLP), B P
cause injuries. Always vent the hoses completely before they are loos-
ened.
Cleaning
■ Never use acidic or alkaline cleaning agents to clean the spray gun.
■ Never use cleaning agents based on halogenated hydrocarbons.
Point of use
■ Never use the spray gun in the vicinity of ignition sources, such as
naked flames, burning cigarettes or non-explosion-proof electrical
equipment.
■ Only use the spray gun in well ventilated rooms.
General
■ Never point the spray gun at human beings.
■ Comply with the local regulations for safety, accident prevention, occu-
pational health and safety and environmental protection.
■ Heed the accident prevention regulations.

3. Intended Use

The spray gun is used to apply paints, lacquers and other sprayable me-
dia on suitable substrates.

4. Description

The compressed air required for spraying is supplied at the compressed
air connection. Pull the trigger to the first pressure point to activate the
pre-air control. Continue pulling the trigger to pull the paint needle out of
the fluid tip: the material flows without pressure out of the fluid tip and is
atomised by the compressed air flowing out of the air cap.

5. Scope of Delivery

■ Spray gun with nozzle set B F RP / B F HVLP/ B P and gravity flow cup
■ Tool kit
■ CCS clips
■ Operating Instructions
Alternative version
■ Gravity flow cups made of PVC or aluminium with different capacities
After unpacking, check:
■ Spray gun damaged
■ Complete scope of supply