Safety data for the Sendix 58xxFS2 encoders
Relevant Standards
Classification
System structure
PFH
value
d
Service life
Safety data for the Sendix 58xxFS3 encoders
Relevant Standards
Classification
System structure
PFH
value
d
Service life
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 03
EN ISO 13849-1:2015
EN ISO 13849-2:2012
EN 61800-5-2:2007
PLd / SIL2
2 channels (cat. 3)
-8
-1
2.16 x 10
h
20 years
EN ISO 13849-1:2015
EN ISO 13849-2:2012
EN 61800-5-2:2007
PLe / SIL3
2 channels (cat. 4)
-8
-1
1.09 x 10
h
20 years
EMC
Relevant Standards
UL - Underwriters Laboratories
UL approval
Relevant Standards
Maximum air humidity
Environment
ATEX
Relevant Standards
EN 55011 class
B:2009 / A1:2010
EN 61326-1:2013
EN 61326-3-1:2008
File 224618
UL 61010-1
Indoor use, outdoor use pos-
sible, not designed for direct
UV radiation.
93 %, 40°C [104°F]
Dry / Wet
EN 60079-0:2012 / A11:2013
EN 60079-15:2010
EN 60079-28:2015
EN 60079-31:2014
Zone 2/22 (optional, variant)
EN - 43