Herunterladen Inhalt Inhalt Diese Seite drucken

Camille Bauer SIRAX MT7100 Betriebsanleitung Seite 55

Dreiphasen-netzmessgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

43497
V_SWELL_VALUE_N_9
43499
V_SWELL_YEAR_N_9
43500
V_SWELL_MONTH_N_9 Voltage Swell Month @ n-9
43501
43502
V_SWELL_HOUR_N_9
43503
V_SWELL_MINUTE_N_9 Voltage Swell Minute @ n-9
43504
V_SWELL_SECOND_N_9
43505
V_SWELL_DURATION_N_9
43506
V_SWELL_QUERY_N_9
43507
V_SWELL_VALUE_EE-
43509
V_SWELL_YEAR_EEPROM
43510
V_SWELL_MONTH_EEPROM
43511
V_SWELL_DAY_EEPROM
43512
V_SWELL_HOUR_EEPROM
43513
43514
43515
43516
U_SWELL_Query_EE-
43517
43519
43520
43521
43522
43523
43524
43525
43526
43527
43529
43530
PM 1001941 000 00
Downloaded from
www.Manualslib.com
Voltage Swell RMS Value (between 10% and 90%
"Nominal_Star_Voltage") @ n-9
Voltage Swell Year @ n-9
V_SWELL_DAY_N_9
Voltage Swell Day @ n-9
Voltage Swell Hour @ n-9
Voltage Swell Second @ n-9
Voltage Swell Duration [ms] @ n-9
Voltage Swell Type:
0: ND
1: V_L1N
2: V_L2N
3: V_L3N
4: V_L1L2
5: V_L2L3
6: V_L3L1
Voltage Swell RMS Value (between 10% and 90%
PROM
"Nominal_Star_Voltage") EEPROM Data
Voltage Swell Year EEPROM Data
Voltage Swell Month EEPROM Data
Voltage Swell Day EEPROM Daten
Voltage Swell Hour EEPROM Daten
V_SWELL_MINUTE_EE-
Voltage Swell Minute EEPROM Daten
PROM
V_SWELL_
Voltage Swell Second EEPROM Daten
SECOND_EEPROM
V_SWELL_
Voltage Swell Duration [ms] EEPROM Daten
DURATION_EEPROM
Voltage Swell Type:
PROM
0: ND
1: V_L1N
2: V_L2N
3: V_L3N
4: V_L1L2
5: V_L2L3
6: V_L3L1
V_INERRUPTION_
Voltage INERRUPTION RMS Value (between 10% and
VALUE_N_0
90% "Nominal_Star_Voltage") @ n-0
V_INERRUPTION_
Voltage INERRUPTION Year @ n-0
YEAR_N_0
V_INERRUPTION_
Voltage INERRUPTION Month @ n-0
MONTH_N_0
V_INERRUPTION_
Voltage INERRUPTION Day @ n-0
DAY_N_0
V_INERRUPTION_
Voltage INERRUPTION Hour @ n-0
HOUR_N_0
V_INERRUPTION_
Voltage INERRUPTION Minute @ n-0
MINUTE_N_0
V_INERRUPTION_
Voltage INERRUPTION Second @ n-0
SECOND_N_0
V_INERRUPTION_
Voltage INERRUPTION Duration [ms] @ n-0
DURATION_N_0
V_INERRUPTION_
Voltage INERRUPTION Type:
QUERY_N_0
0: ND
1: V_L1N
2: V_L2N
3: V_L3N
4: V_L1L2
5: V_L2L3
6: V_L3L1
V_INERRUPTION_
Voltage INERRUPTION RMS Value (between 10% and
VALUE_N_1
90% "Nominal_Star_Voltage") @ n-1
V_INERRUPTION_
Voltage INERRUPTION Year @ n-1
YEAR_N_1
V_INERRUPTION_
Voltage INERRUPTION Month @ n-1
MONTH_N_1
Three phase meter SIRAX MT7100/MT7150
manuals search engine
Float
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Float
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Float
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Unsigned short
R
Float
R
Unsigned short
R
Unsigned short
R
55/60

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sirax mt7150

Inhaltsverzeichnis