Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes; Installation Instructions; Symbol Description - HANSGROHE Logis 120 serie Gebrauchsanleitung, Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C / 4 min
Assembly (see page 31)
English

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Operation (see page 34)
• Hansgrohe recommends not to use as
• 71837000 / 71839000
Dimensions (see page 36)
Flow diagram (see page 36)
Spare parts (see page 40)
Cleaning (see page 39)
Test certificate (see page 44)
drinking water the first half liter of water
drawn in the morning or after a pro-
longed period of non-use.
After periods of prolonged non-use, but at
least every third day, the fittings must be
opened with the handle in hot and cold
position to prevent stagnation in the
connecting lines. Let the water run until the
water temperature is constant.
with EcoSmart
®
without EcoSmart
®

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis