To associate a wireless Think controller, start the radio channel search:
Setting wireless device
-
Open the radio channel. To do that, press on SW1. The LED D19 will remain solid red. Once open,
you have 15 minutes to make the association. If that period of time expires, start the process over
again. Remember not to open more than one module at the same time, it may alter the process.
You can also open the channel association radio through the Blueface and Think (see section System
parameters).
IMPORTANT: not to open more than one radio channel at the same time, it may alter the process.
-
Start the radio channel search, to do so, press Airzone to start the search.
-
The controller will display the different wireless zone modules found, with the signal level of each one of them. Select
the wanted module and press "Check", the selected module will begin to "beep" to be identified. Verify the range is
correct (30% minimum) and confirm.
IMPORTANT: Before selecting the zone module which will be associated with the thermostat, check that this module is the
desired one. If this module is not the correct one, use the control bar to select another module and check again.
IMPORTANT: The thermostat will display first the wireless zone modules which are closer to it. Remember to configure this
thermostat near the wireless control module to associate for greater comfort.
Zone address
Select the zone associated to the thermostat. All the zones have a corresponding control output (output for motorized
elements or control relay for radiant elements). For example, the zone 1 will control the control relay output O1 of the Airzone
Control Module of Radiant Elements (AZDI6OUTPUT8).
Associated outputs (only if there are previously configured secondary)
If necessary, the system allows you to associate more than one zone module to a zone. It is possible to control multiple zone
module from the same thermostat.
Important: You must select the zone/s that you want to configure as secondary outputs before pressing "Confirm".
Thermostat settings (only available in thermostats Blueface)
Select the operation of the thermostat:
-
Master: Controls all the parameters of the installation.
-
Zone: Controls all the parameters of the zone.
Control stages (only available in installations with AZDI6OUTPUT8 modules)
Select stages to be controlled in heating and cooling: Air, Radiant or Combined.
Manufacturer ID (only available in installations with AZDI6MCIFR [C/R] modules)
Select the control protocol you want to use in the AC unit to be controlled. Check the compatible IR gateway modules at:
http://doc.airzone.es/producto/Gama_AZ6/Airzone/Distribuido/Fichas_tecnicas/Compatibilidades/UC_AZDI6MCIFR_MUL.pdf
Master address (only available for zone thermostats in installations configured as four-pipe, only if a Blueface thermostat has
been previously configured as master)
Select the master thermostat address with which the thermostat is associated. Thus, this master thermostat will impose the
operation mode to the thermostat.
Other settings
Press to finish the initial setup process, or access the advanced settings (system address, control stages, etc.) to change any
other settings. Activate the basic function if required (see Advanced Settings, Zone settings).