- safety gloves to avoid injuries from sharp edges
or knives,
- safety goggles to avoid eye injuries from flying
parts.
• It is imperative that the following situations are
avoided at all times: Premature interruption of the
cutting operation (planing cuts which do not com-
plete the entire length of the workpiece; planing of
uneven pieces of wood which do not lie flat on the
infeed table).
• Important! If the primary mains connection is in a
poor condition there is a risk of short-circuits when
the machine is switched on. This may also affect
other functions (e.g. the lighting up of indicator
lamps). Should there be any faults in the primary
mains connection, please contact your local elec-
tricity supplier to advice and information.
Residual risks
Even when the machine is used as prescribed it is
still impossible to eliminate certain residual risk fac-
tors. There is a risk of the following injuries in con-
nection with the required operation of the machine:
• m WARNING! Danger of injury!
of fingers and hands by contact with the blade
shaft at uncovered areas when changing tools.
These can also be crushed by opening the guard.
• Eye injuries
• on the infeed and discharge opening by
dangerous recoil
• Danger from current if the electric cables have not
been connected correctly.
• harmful wood duct may be generated if operated
without an extractor or chip bag.
• by catapulted parts
• Metal parts in the workpiece can blunt or destroy
the blades.
• Lung damage if no suitable protective dust mask
is used.
m WARNING! Hearing damage!
A longer stay in the immediate vicinity of the running
unit may cause hearing damage.
Wear ear protectors!
Despite the observance of the operating instructions
there still may be some hidden residual risks.
Warning! This electric tool generates an electro-
magnetic field during operation. This field can impair
active or passive medical implants under certain
conditions. In order to prevent the risk of serious or
deadly injuries, we recommend that persons with
medical implants consult with their physician and the
manufacturer of the medical implant prior to operat-
ing the electric tool.
Emergency procedure
Conduct a first-aid procedure adequate to the
injury and summon qualified medical attendance as
quickly as possible. Protect the injured person from
further harm and calm them down.
28
GB
For the sake of eventual accident, in accordance
with DIN 13164, a workplace has to be fitted with a
first-aid kit. It is essential to replace any used mate-
rial in the first-aid kit immediately after it has been
used. If you seek help, state the following pieces of
information:
1. Accident site
2. Accident type
3. Number of injured persons
4. Injury type(s)
6. Technical data
Technical data
Number of knives
Cutter block rpm
Dimensions
780 x 440 x 455 mm
Weight
Technical data – Surfacing
Max planing width
Max chip removal
Ripping fence l x h
Ripping fence
tilting angle
Surfacing table
size
Technical data – Thicknessing
Max planing width
Max planing
thickness
Max chip removal
Thicknessing table
size
Drive
Motor V/Hz
Consumption
power P1
Subject to technical changes!
Sound
Sound values were measured in accordance with
EN 61029.
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
WA
Uncertainty K
WA
Wear ear-muffs.
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Keep the noise emissions and vibrations to a
minimum!
• Only use appliances which are in perfect working
order.
• Service and clean the appliance regularly.
• Adapt your working style to suit the appliance.
• Do not overload the appliance.
• Have the appliance serviced whenever necessary.
• Switch the appliance off when it is not in use.
2 pieces
8000 1/min
23 kg
204 mm
2 mm
520 x 102 mm
90°–45°
737 x 210 mm
204 mm
120 mm
2 mm
250 x 204 mm
230V~ / 50 Hz
1250 W
82 dB(A)
3 dB
93 dB(A)
3 dB