Herunterladen Inhalt Inhalt Diese Seite drucken

Sharp XG-MB50X Serviceanleitung Seite 27

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

No.
Adjusting point
15
RS232C opera-
tion check
16
Model name and
version check
17
Delivery set-
tings
* Writing a software program (before main PWB is mounted)
Use the DLP Composer Lite Ver. 4.2 or higher to download the firmware.
After writing the specified version of firmware to the PWB using the RS232C cable, check the version of the written
firmware.
If no software program is written, all three LEDs light up in the chassis inspection process.
1. Calling and quitting the process mode with the control keys on this model.
∗ Although it is possible for the process OUT to exit using the process menu, the IN/OUT toggle command is also
available considering the existing specification.
1-1. Calling and quitting
With the menu not displayed, press the "ENTER", "ENTER", "VOL+", "VOL-", "ENTER", "ENTER" and "MENU"
keys on the remote control (one for C50/45 or P25/20 system is also usable) or on the main unit.
1-2. Others
Press the S2551 process key (toggle) on the main PWB to call and quit the process menu.
Note: When adjusting in the process mode, set a signal with a vertical frequency of 60 Hz or no signal. (May not be
properly adjusted with other signals.)
2. Resetting the lamp timer for this model
2-1. Resetting procedure
In Stand-by, run this command to clear the operating time of the lamp to 0 and turn on the power.
Press and hold """, "ENTER", and "MENU", and then press the "STANDBY/ON" key of the set.
3. Forced disabling of the System-Lock of this model
3-1. Disabling procedure
With System-Lock input window onscreen, press the "MENU", "ENTER", "ENTER", "MENU", "ENTER", "ENTER"
and "MENU" keys, in this order, on the remote controller.
Adjusting conditions
1. Connect the unit and a PC
with the RS232C cable.
1. Select the following group.
Group : INFO/VERSION.
Adjusting procedure
1. Send a command from the PC, and check it func-
tions correctly.
1. The model name appears in the MODEL field, and
the firmware version in the VERSION field. Check
that they are correct.
1. Make the following settings.
Destination
Process
adjustment
USA
SS4
China
SS6
Others
SS3
27
XG-MB50X
XR-11XC
XR-10X/S
XR-20X/S
Remote control
adjustment
Factory setting at 4
Factory setting at 6
Factory setting at 3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Xr-11xcXr-10xXr-10sXr-20xXr-20s

Inhaltsverzeichnis