7.3 IO-Link-Geräteparameter für ICB12, ICB18 und ICB30
Device parameters
Parameter
Index
Name
Hex(Dec)
Vendor Name
0x10(16)
Vendor Text
0x11(17)
Product Name
0x12(18)
Product ID
0x13(19)
Product Text
0x14(20)
Serial Number
0x15(21)
Hardware Revision
0x16(22)
Firmware Revision
0x17(23)
Application
0x18(24)
Specific Tag
Error Count
0x20(32)
Device Status
0x24(36)
Detailed Device
Status
Temperature
fault
Temperature
0x25(37)
over-run
Temperature
under-run
Process-DataInput
0x28(40)
Subindex
Access
Hex(Dec)
0x00(0)
R
0x00(0)
R
www.gavazziautomation.com
0x00(0)
R
e.g. ICB12S30F04A2IO
0x00(0)
R
e.g. 5709870393070
0x00(0)
R
Inductive Proximity Sensor
0x00(0)
R
0x00(0)
R
0x00(0)
R
0x00(0)
R/W
0x00(0)
R
0x00(0)
R
0x01(1)
R
0x02(2)
R
0x03(3)
R
0x00(0)
R
Rev.00 | IBS04, ICS05, ICS08, ICB12, ICB18, ICB30 Induktive Sensoren mit IO-Link-Schnittstelle | © 2018 | CARLO GAVAZZI Automation
Default value
Carlo Gavazzi
(Sensor name)
(EAN code of product)
(Unique serial number)
e.g. LR24101830834
(Hardware revision)
e.g. v01.00
(Software revision)
e.g. v01.00
***
Any string up to 32 characters
-
0 = Device is operating properly
-
-
-
-
-
Data Type
Data range
(Length)
-
StringT (13)
-
StringT (25)
-
StringT (20)
-
StringT (13)
-
StringT (26)
-
StringT (13)
-
StringT (6)
-
StringT (6)
StringT (32)
0 to 65535
UIntegerT16
2 = Out-of-specification
UIntegerT8
4 = Failure
-
OctetStringT (3)
-
OctetStringT (3)
-
OctetStringT (3)
0 to 15
UIntegerT16