3
Safety
WARNING!
•
The 30S/55S with 3 phase motor may only be connected to a grounded socket of the voltage
stated on the machine data plate.
•
Any damaged electrical component should immediately be replaced with a genuine spare
part. Such work may only be performed by a person with the necessary knowledge of
electrical equipment. Other damaged parts should also be replaced with genuine parts in
order to reduce the risk of personal injury.
•
The appliance must be disconnected prior to any intervention. Disconnect by unplugging the
power supply/plug. or uncoupling the compressed air connection.
•
Before starting, the operator must ensure that the appliance is correctly configured.
•
During starting, the appliance may move in a sideways direction. You should therefore always
be sure to hold onto the appliance when starting.
•
Any damaged component must be replaced with a new genuine part in order to avoid the
danger of e.g. compression injuries, exposure to dust, etc.
•
It is prohibited to lift the appliance by the handle. Instead, lift by the frame's lifting loop
(optional). The receptacle must be empty when lifting. See the '6.2 Transport and lifting'
section.
•
It is prohibited to be underneath the appliance when it is being lifted. See the '6.2 Transport
and lifting' section.
•
The eccentric catches holding the collecting receptacle must be secured by locking cotters.
•
Hot or red-hot material, flammable fluids, explosive or health-impairing fumes or dust that
could cause an explosion may not be sucked into the appliance. Neither may the appliance be
used in spaces where such material exists, i.e. an explosive atmosphere.
•
For reasons of safety, do not put the vacuum hose inlet near the eyes, ears or other part of
the body.
•
Anti-static vacuum hoses and hose fittings should be used in order to reduce the danger of
sparks and dust explosions.
•
Take care not to spread dust when changing the plastic sack or bag and when replacing the
micro-filter.
•
Wear an approved breathing mask in the case of hazardous dust.
•
Do not run the appliance for more than 1 minute when it is almost or fully throttled. Little or
no airflow could result in overheating of the fan and motor. Avoid touching the fan/motor as
this could cause burns.
•
The 30S/55S is not classified as a wet vacuum cleaner. Large amounts of water may not be
sucked into the unit. However, it may be used for damp material and in a damp environment.
4
Description
4.1
Function
The 30S/55S series is an industrial vacuum cleaner. 30S/55S with 3-phase high pressure side
channel fan.
Dust separation takes place in three stages:
•
Stage 1 is a receiver or cyclone for coarse particles.
•
Stage 2 is a fine filter.
•
Stage 3 is a micro-filter (optional) with degree of separation > 99.997% (DOP).
30S/55S Series
EN
11