(7) Battery compartment cover
(8) Laser warning label
(9) Serial number
(10) Holder (LB 10)
(11) 1/4" screw of the holder
(12) Magnet
(13) Screw hole of the holder
A)
(14) Ceiling clip (DK 10)
A)
(15) Tripod (BT 150)
(16) Telescopic shaft (BT 350)
A)
(17) Universal holder (BM 1)
A)
(18) Rotating mount (RM 10)
A)
(19) Laser goggles
A)
(20) Laser target plate
A)
(21) Protective bag
A) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Line laser
Article number
A)
Working range
B)C)
Levelling accuracy
Self-levelling range
Levelling time
Operating temperature
Storage temperature
Max. altitude
Relative air humidity max.
Pollution degree according to
IEC 61010-1
Laser class
Laser type
C
6
Divergence
Tripod mount
Batteries
Weight according to
EPTA-Procedure 01:2014
Dimensions (length × width × height)
– Without holder
– With holder LB 10
Bosch Power Tools
The serial number (9) on the type plate is used to clearly identify your
A)
measuring tool.
Assembly
Inserting/Changing the batteries
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
Press the locking mechanism (6) upwards to open the bat-
tery compartment cover (7) and remove the battery com-
partment cover. Insert the batteries.
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
GLL 2-15 G
compartment.
3 601 K63 W..
The battery indicator (2) always indicates the current status
of the battery.
15 m
If the batteries are running low, the laser lines will gradually
±0.3 mm/m
become dimmer.
±4°
If the batteries are almost empty, the battery indicator (2)
< 4 s
will flash continuously. The laser lines will flash for 5 seconds
every 5 minutes.
–10 °C to +50 °C
If the batteries are empty, the laser lines and the battery in-
–20 °C to +70 °C
dicator will flash once before the measuring tool switches
2000 m
off.
90%
Always replace all the batteries at the same time. Only use
D)
batteries from the same manufacturer and which have the
2
same capacity.
u
2
500−540 nm, < 10 mW
10
50 × 10 mrad (full angle)
Operation
1/4"
4 × 1.5 V LR6 (AA)
Starting Operation
0.57 kg
u
u
126 × 63 × 115 mm
145 × 63 × 134 mm
Line laser
Protection rating
A) The working range may be reduced by unfavourable environ-
mental conditions (e.g. direct sunlight).
B) At 20–25 °C
C) The values stated presuppose normal to favourable environ-
mental conditions (e.g. no vibration, no fog, no smoke, no direct
sunlight). Extreme fluctuations in temperature can cause devi-
ations in accuracy.
D) Only non-conductive deposits occur, whereby occasional tem-
porary conductivity caused by condensation is expected.
Take the batteries out of the measuring tool when you
are not using it for a prolonged period of time. The bat-
teries can corrode and self-discharge during prolonged
storage in the measuring tool.
Protect the measuring tool from moisture and direct
sunlight.
Do not expose the measuring tool to any extreme tem-
peratures or fluctuations in temperature. For example,
do not leave it in a car for extended periods of time. If it
has been subjected to significant fluctuations in temper-
ature, first allow the measuring tool to adjust to the ambi-
ent temperature and then always carry out an accuracy
check before continuing work (see "Accuracy Check of
the Measuring Tool", page 14).
English | 13
GLL 2-15 G
IP 64
1 609 92A 5EM | (20.03.2020)