TECHNICAL DATA
a-LIFE2 HP DFIV/DLIV
ELECTRICAL DATA
Power supply
4 PIPES SYSTEM CONFIGURATION
ENERGY EFFICIENCY
COOLING (EN14511 VALUE)
FCEER
FCEER Class
HEATING ONLY (EN14511 VALUE)
FCCOP
FCCOP Class
PERFORMANCE
MIN SPEED
Fan Power Input
Air flow rate
Total capacity in cooling mode
Total Net Cooling Capacity
Sensible capacity in cooling mode
Net sensible cooling capacity
Net latent power in cooling
Max water flow
Pressure Drop in cooling mode
Total capacity (heating mode)
Total Net Heating Capacity
Water flow in heating mode
Pressure drop in heating mode
Sound Pressure
Sound Power
MED SPEED
Fan Power Input
Air flow rate
Total capacity in cooling mode
Total Net Cooling Capacity
Sensible capacity in cooling mode
Net sensible cooling capacity
Net latent power in cooling
Max water flow
Pressure Drop in cooling mode
Total capacity (heating mode)
Total Net Heating Capacity
Water flow in heating mode
Pressure drop in heating mode
Sound Pressure
Sound Power
MAX SPEED
Fan Power Input
Air flow rate
Total capacity in cooling mode
Total Net Cooling Capacity
Sensible capacity in cooling mode
Net sensible cooling capacity
Net latent power in cooling
Max water flow
Pressure Drop in cooling mode
Total capacity (heating mode)
Total Net Heating Capacity
Water flow in heating mode
Pressure drop in heating mode
Sound Pressure
Sound Power
SIZE AND WEIGHT
A
B
H
Operating weight
Notes:
1 Room temperature 27°C d.b./18,9°C w.b., Chilled water (in/out) 7°C/12°C.
2 Room temperature 20 °C d.b., hot water (in/out) 65/55 °C
3 Sound pressure level in free field on a reflective surface, 1 m from fan front and 1 m from the ground. Non -binding value obtained fron sound power level.
4 Sound power on the basis of measurements made in compliance with ISO 3741 and Eurovent 8/2.
5 Unit in standard configuration/execution, without optional accessories.
6 Values in compliance with EN14511-3:2013.
7 Values in compliance with [REGULATION (UE) N.2016/2281]
Certified data in EUROVENT
0304
0404
V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50
kW/kW
37
40
(1)(6)
F
E
(2)(6)
kW/kW
27
29
G
G
(1)
W
52,0
52,0
m³/h
392
435
(1)
(1)
kW
2,08
2,21
kW
2,03
2,16
(1)(6)(7)
kW
1,69
1,82
(1)
(1)(6)(7)
kW
1,64
1,77
kW
0,39
0,39
(1)(6)(7)
(1)
l/s
0,10
0,11
(1)
kPa
16
14
kW
1,50
1,59
(2)
(2)(6)
kW
1,55
1,64
l/s
0,04
0,04
(2)
(2)
kPa
6
7
(3)
dB(A)
42
45
dB(A)
51
54
(4)(7)
W
71,0
71,0
(1)
(1)
m³/h
500
555
kW
2,31
2,70
(1)
(1)(6)(7)
kW
2,24
2,63
kW
1,90
2,24
(1)
kW
1,83
2,17
(1)(6)(7)
(1)(6)(7)
kW
0,41
0,46
l/s
0,11
0,13
(1)
(1)
kPa
20
22
kW
1,67
1,95
(2)
kW
1,74
2,02
(2)(6)
(2)
l/s
0,04
0,05
kPa
7
10
(2)
(3)
dB(A)
45
52
(4)(7)
dB(A)
54
61
W
95,0
95,0
(1)
m³/h
561
623
(1)
(1)
kW
2,88
3,28
kW
2,79
3,19
(1)(6)(7)
(1)
kW
2,39
2,77
kW
2,30
2,67
(1)(6)(7)
kW
0,49
0,51
(1)(6)(7)
(1)
l/s
0,14
0,16
kPa
32
32
(1)
(2)
kW
2,08
2,36
kW
2,17
2,46
(2)(6)
l/s
0,05
0,06
(2)
(2)
kPa
11
14
dB(A)
52
56
(3)
(4)(7)
dB(A)
61
65
(5)
mm
650
650
mm
215
215
(5)
mm
450
450
(5)
(5)
kg
15
16
0504
0604
0704
0804
58
69
43
49
D
D
E
E
46
55
31
35
F
E
G
G
38,0
38,0
67,0
67,0
464
516
584
649
2,28
2,92
3,22
3,50
2,24
2,88
3,15
3,43
1,84
2,37
2,49
2,78
1,80
2,33
2,42
2,71
0,44
0,55
0,73
0,72
0,11
0,14
0,15
0,17
4
7
9
13
1,78
2,28
2,30
2,50
1,82
2,32
2,37
2,56
0,04
0,06
0,06
0,06
8
13
4
5
34
41
38
41
43
50
47
50
53,0
53,0
96,0
96,0
525
583
767
852
3,04
3,23
3,57
4,49
2,99
3,18
3,48
4,40
2,48
2,66
2,84
3,74
2,43
2,61
2,74
3,64
0,56
0,57
0,73
0,75
0,15
0,15
0,17
0,21
8
9
12
21
2,37
2,52
2,55
3,21
2,43
2,58
2,65
3,31
0,06
0,06
0,06
0,08
14
16
5
8
41
44
41
49
50
53
50
58
75,0
75,0
132
132
705
783
1004
1116
3,74
4,14
4,62
5,20
3,67
4,07
4,49
5,07
3,15
3,53
3,91
4,44
3,08
3,45
3,78
4,31
0,59
0,61
0,71
0,76
0,18
0,20
0,22
0,25
12
15
19
29
2,92
3,24
3,30
3,72
3,00
3,31
3,43
3,85
0,07
0,08
0,08
0,09
21
25
9
11
47
51
52
55
56
60
61
64
850
850
1050
1050
215
215
215
215
450
450
450
450
21
22
25
26
0904
1004
1104
1204
43
48
41
44
E
E
E
E
30
34
29
32
G
G
G
G
112
112
168
168
923
1026
1381
1534
4,83
5,40
6,90
7,40
4,72
5,29
6,74
7,24
3,88
4,42
5,83
6,25
3,77
4,31
5,66
6,08
0,95
0,98
1,07
1,15
0,23
0,26
0,33
0,35
21
24
10
29
3,43
3,84
4,91
5,26
3,54
3,95
5,07
5,43
0,08
0,09
0,12
0,13
8
9
26
30
49
51
54
54
58
60
63
63
135
135
179
179
1078
1198
1547
1719
5,70
6,25
7,50
8,10
5,57
6,12
7,32
7,92
4,67
5,15
6,46
7,03
4,53
5,01
6,28
6,85
1,03
1,10
1,04
1,07
0,27
0,30
0,36
0,39
29
33
12
35
4,05
4,44
5,33
5,76
4,19
4,58
5,51
5,94
0,10
0,11
0,13
0,14
10
12
30
35
51
54
55
57
60
63
64
66
149
149
194
194
1390
1544
1740
1933
6,20
7,20
8,05
8,60
6,05
7,05
7,86
8,41
5,14
5,91
6,99
7,32
4,99
5,76
6,80
7,13
1,06
1,29
1,06
1,28
0,30
0,34
0,38
0,41
34
43
14
40
4,41
5,12
5,72
6,12
4,56
5,27
5,92
6,31
0,11
0,12
0,14
0,15
12
16
35
39
54
59
57
59
63
68
66
68
1250
1250
1450
1450
215
215
215
215
450
450
450
450
29
31
32
35