BTL7-S5 _ _ (B)-M _ _ _ _ -A/B(8)-SA211/SA311-S32/S147/KA _ _ /FA _ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
Supporting rod made of non-magnetizable material
Fig. 4-7: Example 2, transducer installed with supporting rod
4.4

Electrical connection

Depending on the model, the electrical connection is made
using a cable or a connector.
The connection or pin assignments for the respective
version can be found in Tables 4-2 to 4-4.
Note the information on shielding and cable
routing on page 12.
4.4.1

Connector type S32

BTL7 standard
Pin
BTL7-S5_ _-...-S32
BTL7-S5_ _B-...-S32
1
+Clk
2
+Data
3
–Clk
4
Not used
1)
5
–Data
6
GND
7
10 to 30 V
8
Not used
1)
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Communication line
2)
Tab. 4-2:
Connection assignment BTL7...-S32
Fig. 4-8: Pin assignment of S32 (view of connector pins of
transducer), 8-pin M16 circular plug
www.balluff.com
Magnet
(e.g. BTL-P-1028-15R)
BTL7 USB
configurable
BTL7-S510-...-S32
BTL7-S510B-...-S32
+Clk
+Data
–Clk
La
2)
–Data
GND
10 to 30 V
Lb
2)
4.4.2

Connector type S147

BTL7 standard
Pin
BTL7-S5_ _-...-S147
BTL7-S5_ _B-...-S147
1
–Data
2
+Data
3
+Clk
4
–Clk
5
10 to 30 V
6
GND
7
Not used
1)
Unassigned leads can be connected to the GND on the controller side
1)
but not to the shield.
Tab. 4-3:
Connection assignment BTL7...-S147
Fig. 4-9: Pin assignment of S147 (view of connector pins of
transducer), 7-pin M16 circular plug
4.4.3

Cable connection

BTL7 standard
Cable
BTL7-S5_ _-...-KA
color
BTL7-S5_ _-...-FA
BTL7-S5_ _B-...-KA
BTL7-S5_ _B-...-FA
YE yellow
+Clk
GY gray
+Data
PK pink
–Clk
RD red
Not used
1)
GN green
–Data
BU blue
GND
BN brown 10 to 30 V
WH white
Not used
1)
1)
Unassigned leads can be connected to the GND on the controller side
but not to the shield.
Communication line
2)
Tab. 4-4:
Connection assignment BTL7... cable
Clk, Data and supply are twisted in pairs (see
Fig. 4-10).
BTL7 USB
configurable
BTL7-S510-...-KA
BTL7-S510-...-FA
BTL7-S510B-...-KA
BTL7-S510B-...-FA
+Clk
+Data
–Clk
La
2)
–Data
GND
10 to 30 V
Lb
2)
english