TRP 100 M, TRP 100 W
Press the ENTER key.
Press
or
to select ON or OFF to switch the
function on or off.
Confirm the BACK key to return to the standard
display.
11.3 Temperature unit, maximum temperature
Two functions can be set in this menu:
Temperature unit display
Display can be set to degrees Celsius or degrees
Fahrenheit.
Maximum temperature
Define an adjustable maximum temperature.
Press and hold the MENU key, the BACK key and
the ENTER key for five seconds.
SP display flashes.
Press the ENTER key. °C display flashes.
Press
or
to select °C or °F.
NOTE
NOTE
° C is most widely used in most European countries.
Press the ENTER key. Maximum temperature
display flashes
Press
or
to specify the maximum
temperature.
Confirm with ENTER.
Confirm the BACK key to return to the standard
display.
www.dimplex.de/en
11.4
Key lock
This function can be used to lock the operating
elements.
Press and hold the BACK key and the ENTER key
for three seconds.
The LOCKED symbol appears in the display.
To unlock, press and hold the BACK key and the
ENTER key again for three seconds.
NOTE
NOTE
No settings can be made if the key lock is activated.
11.5
Restricting functions
The functions, runback timer and the adjustment of the
values for the minimum or maximum temperature can
be locked with a code.
The lock is carried out by defining and entering a four-
digit code.
Press and hold the MENU key, the BACK key and
the ENTER key for 5 seconds. SP display flashes.
Press
or
Confirm with ENTER. The first digit flashes.
Press
or
code between 0 and 9.
Press the ENTER key.
1810/B
to select the KEY LOCK symbol.
to set the first digit of the number
English