en
Description
Graphic G
1 Alarm A1, continuous
red light
2 Alarm A2, alternating
red/black light
Graphic J
1 Battery pre-alarm
Graphic K
1 Calibration adapter
(grey coloured ring)
2 Gas inlet
Graphic M
1 Pump adapter (blue
coloured ring)
2 Gas inlet
3 Dust and water filter
3.2 Intended use
®
Dräger X-am
3500 is a portable gas detector for
clearance measurements and for the continuous
monitoring of the concentration of several gases in
ambient air in the workplace and in explosion-hazard
areas.
The X-am 3500 allows measuring up to 4 gases in
accordance with the DrägerSensors (XXS O
LC, XXS CO LC, XXS NO
PR) which are installed. The gas detector can be
operated in pump mode or in diffusion mode.
3.3 Limitations on use
The gas detector is not suitable for measuring process
gasses.
Operation of the gas detector in the charging cradle in a
vehicle is only permitted under the following conditions:
– Acoustic signalling must be deactivated (with the
help of the PC software CC-Vision) so that the driver
is not distracted.
3 STEL alarm
4 TWA alarm
2 Battery main alarm
3 Exhaust
4 Locking screw
4 Exhaust
5 Locking screw
, XXS H
2
, XXS SO
and CatEx 125
2
2
3.4 Approvals
A copy of the rating plate, the declaration of conformity
and the sensor data relevant for measurement
purposes are provided in the enclosed supplementary
documentation (part no. 90 33 655).
Explosion protection:
BVS 17 ATEX E 040 X certifies the intended use in
explosion-hazard areas and the measuring function for
explosion protection. PFG 19 G 001 X certifies the
measurement of oxygen deficiency and oxygen surplus
as well as the measuring function for toxic gases. See
the supplementary documentation for certified gases
and measured values (part no. 90 33 655).
CSA-specific information:
Only the combustible gas part of this instrument has
been tested for measuring accuracy.
Radio approval (X-am 8000 only):
The information for radio approval can be viewed in the
menu. For further information, see the following
chapter: "Opening information", page 38.
Approval-related accessories:
This chapter contains an overview of the key parts
covered by the BVS and PFG certification. Information
on other parts can be found in the spare parts list or can
be requested from Dräger Service. The same ambient
conditions that apply for the gas detector also apply for
the accessory. For further information see: "Gas
S
2
detection instrument", page 49.
Description
Carrying strap
Calibration adapter
Pump adapter with dust
and water filter
Induction charger
The data logger is not part of the technical suitability
test.
3.5 Label
The energy supply label has a mark for a service label.
Here, a maximum of one service label and one year-
point label may be attached one on top of the other.
Further labels, conductive labels or labels with
conductive material or parts can have a negative effect
on inductive charging.
Part number
8326823
8326821
8326820
8325825
®
X-am