Operation
Comfortable SLEEP
Before going to bed,you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring
you a sound sleep.
AUTO
Operation Mode
AM
1.In COOL,DRY mode
1 hours after SLEEP mode
SMART
starts, temp.will become 1
higher than temp.setting. After
another 1 hours, temp. rises
by 1
for further 6 hours then stops
Temp.is higher than temp.
setting so that room temperature
won't be too low for your sleep.
SLEEP
operation starts
1 hr
Rises 1
1 hr
Temp.setting
In COOL, DRY mode
2.In HEAT mode
1 hours after SLEEP mode starts,temp will become 2
lower than temp.setting. After another 1 hours, temp
decrease by 2
O
C
further. After more another 3 hours,
temp. rises by 1
O
C
further. The unit will run for further
Press SLEEP
button.
O
C
O
C
further. The unit will run
SLEEP
operation stops
Approx.6hrs
O
Rises 1
C
O
C
Unit stop
3 hours then stops. Temp. is lower than temp. setting
so that room temperature won't be too high for your
sleep.
Temp.setting
1 hr
1 hr
SLEEP
operation starts
3.In SMART mode
The unit operates in corresponding sleep mode, which
adapted to the automatically selected operation mode.
4.When quiet sleeping function is set to 8 hours the
quiet sleeping time can not be adjusted.When TIMER
function is set,the quiet sleeping function can't be set
up.After the sleeping function is set up,if user resets
TIMER function, the sleeping function will be cancelled;
the machine will be in the state of timing-on,if the two
modes are set up at the same time, either of their
operation time is ended first ,the unit will stop
automatically, and the other mode will be cancelled.
Power Failure Resume Function
If the unit is started for the first time, the compressor
will not start running unless 3 minutes have elapsed.
When the power resumes after power failure, the
unit will run automatically, and 3 minutes later the
compressor starts running.
Note to the power failure resume:
press the sleep button ten times in five seconds and
O
C
enter function after hearing four sounds.And press
the sleep button ten times within five seconds and
leave this function after hearing two sounds.
Unit stop
O
Decreases 2
C
Decreases 2
O
C
3 hrs
3 hrs
Rises 1
O
operation stops
In HEAT mode
C
SLEEP
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis