ERROR CODES
Error code
General functions
ERROR TEMPERATURE SENSOR OPEN
This error occurs if there is a faulty sensor, incorrect connections, a
faulty PCB and if the A/D value detected by MICOM is lower than 10.
ERROR TEMPERATURE SENSOR SHORT
This error occurs if there is a faulty sensor, incorrect connections, a
faulty PCB and if the A/D value detected by MICOM is higher than 252.
TARGET TEMPERATURE TEMPERATURE SENSOR
This error occurs if the preheating was not completed and the
temperature in the oven is lower than 120 °C for 30 minutes.
ERROR ABNORMAL TEMPERATURE DETECTION
This error occurs if the temperature in the oven is higher than 250 °C for
10 minutes.
ERROR ABNORMAL TEMPERATURE DETECTION MICROWAVE
This error occurs if the temperature in the oven in the microwave setting
is higher than 210 °C.
ERROR BUTTON SHORT
This error occurs if you press and hold a button for longer than 60 seconds.
This error may occur if water gets into the control panel or if dust
particles stick on theTOUCH PANEL.
ERROR NAK SIGNAL
The NAK signal is given if it takes longer than 10 seconds to switch on
the appliance.
COMMUNICATION ERROR
This error occurs if there is no communication between the main PCB
and the sub PCB for longer than 10 seconds.
ERROR EEPROM OPEN
This error occurs if something goes wrong in the EEPROM communication
when you are setting the power.
ERROR EEPROM READ & WRITE
Eeprom is not used.
If one of these errors occurs, contact the Pelgrim customer service.
EN 58