Mounting and Connection Instructions Block Lock Module BUS-2/BUS-1
7.

Start-up

7.1

Check installation

To ensure reliable functioning, all system parts must be installed correctly. Measure all the lines to
detect possible interruptions or short circuits.
Ensure that there is no ground fault.
7.2

Perform diagnostic mode

Aktivate diagnostic mode:
LED functions:
- LED1
on: DG1 triggered (Tamper switching device )
- LED2
Indicates the state of the switching device
1. Operating mode "Lock function"
(Block Lock, Dead bolt lock, Key Switch SS90)
2. Operating mode "Switch with neutral mid-position"
(Outdoor safety operating unit f.m. 012520)
- LED3
on: DG3 triggered (bolt switching contact)
- LED4
on: DG4 triggered (opening contact)
8.

Final assembly

Mounting in compliance with VdS:
Strain relief of cables:
Before closing the housing, secure the cable binders at the provided retainers .
Seal housing:
Seal the housing after mounting correctly and testing the system by pressing the plastic seals into the
screw openings on the front of the housing.
Clean the seals(free from grease) and cover with the labels (VdS imprint).
After attaching the plastic seals, the housing cannot be opened without destroying the seals.
BUS-2 operation:
BUS-1 operation:
LED2 off
disarmed
LED2 flashes
armed
LED2 static on
outside of the monitoring ranges
LED2 off
no operation (switch neutral mid-position)
LED2 flashes
during operation "armed" or "disarmed"
LED2 static on
outside of the monitoring ranges
Activation via control panel
Remove housing cover