Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
It is a 15-pins D type connector; the available signals are detailed in
the table, the following paragraphs describe the signal characteristics
and use.
Tab. 3
PIN N.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Signal Description

START/STOP: input signal to start or stop the pump. With the
supplied cover connector the START/STOP (+) signal is connected to
the +24 Vdc pin and the START/STOP (-) signal to the GROUND pin:
in this condition the pump automatically starts as soon as the
controller recognises the input supply ("Plug & Pump").
INTERLOCK: input signal to control the pump rotation. With the
supplied cover connector the INTERLOCK (+) signal is connected to
the +24 Vdc pin and the INTERLOCK (-)signal to the GROUND pin.
TV 801 Navigator Bolted Flange User Manual / 87-900-980-01 (D)
SIGNAL NAME
START/STOP (+)
START/STOP (-)
INTERLOCK (+)
INTERLOCK (-)
SPEED SETTING (+)
SPEED SETTING (-)
SOFT START (+)
SOFT START (-)
+24 Vdc
RELAY CONTACT: NORMALLY OPEN
PROGRAMMABLE SET POINT
RELAY CONTACT: NORMALLY OPEN
FAULT OUTPUT
PROGRAMMABLE ANALOG SIGNAL (+)
GROUND PROGRAMMABLE ANALOG SIGNAL (-)
Technical Information
J1 - In-Out
INPUT/
OUTPUT
IN
IN
IN
IN
IN
IN
IN
IN
OUT
OUT
OUT
OUT
OUT
OUT
OUT
219/248
17

Werbung

loading