LED indicator/fault pattern /
LED indicator/fault pattern
Signal interruptions when ob‐
ject is detected /
Signal interruptions when ob‐
ject is detected
The sensor must be disposed of according to the applicable country-specific regulati‐
ons. Efforts should be made during the disposal process to recycle the constituent ma‐
terials (particularly precious metals).
SICK sensors are maintenance-free.
We recommend doing the following regularly:
•
Clean the external lens surfaces
•
Check the screw connections and plug-in connections
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
DISASSEMBLY AND DISPOSAL
Cause /
Cause
Depolarizing property of the
object surface (e.g., tape), re‐
flection /
Depolarizing property of the
object surface (e.g., tape), re‐
flection
Measures /
Measures
Reduce sensitivity or change
the position of the sensor /
Reduce sensitivity or change
the position of the sensor