Herunterladen Inhalt Inhalt Diese Seite drucken

RIB KIT PREMIER 24V Bedienungsanleitung Seite 32

Vorschau ausblenden Andere Handbücher für KIT PREMIER 24V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
G G
B B
POINT A -
CONTROL PANEL FEATURES
POINT B -
SETTINGS
DIP 1 MOTOR ROTATION DIRECTION CHECK
(SEE POINT C)
DIP 2 PROGRAMMING (SEE POINT D AND E)
DIP 1-2 STORING/ERASING RADIO CODES FOR
MOTOR CONTROL (ONLY CRX CONTROL
BOARD) (SEE POINT G, H AND I)
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (SEE POINT F)
DIP 3 ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4 ON - Photocells active only in closing
OFF - Photocells always active
DIP 5 ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6 ON - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
OFF - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7 ON - current sensor DISABLED
OFF - current sensor ENABLED
DIP 8 ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9 ON - Hammering on both complete open and complete close
position to ease Manual Release
J1
SEC.TRANSF.
Connection to secondary coil of transformer
J2a
MOTOR 1
Connection MOTOR 1 (no polarity)
J2b
MOTOR 2
Connection MOTOR 2 (no polarity)
J3
AERIAL
Radio Antenna
COM.
Common contact (common line for all the
command and safety inputs)
PHOT.
Photocells contact (NC)
K BUTT.
Single pulse contact (NO)
SIGNAL
Gate open state and battery state output
indicator (12Vdc 3W max)
PED. BUTT.
Pedestrian opening contact (NO)
EDGE
Safety strip contact (NC)
A -
- 24Vdc accessories power supply
A+TEST
+ 24Vdc safety strip self-test power supply
A+
+ 24Vdc accessories power supply
BLINKER
- 24Vdc flashing light (cod. ACG7061) power
supply. Pay attention to the polarity
LOCK
-12Vdc electrical lock power supply (MAX 15W 12V)
J4
SW
Connector for microprocessor firmware upgrade.
Do not fit any jumper into the connector.
J5
BATTERY
Connector for charge card of 24Vdc battery
CHARGER
(cod. ACG4661)
J6
RADIO
Built-in radio module (model CRX), or
connector for radio receiver RIB, 24 Vdc supply
L1 - N
Main power supply 230 Vac 50/60 Hz
(120V/60Hz upon request)
- Hammering before opening to ease electric lock unlocking
OFF- no impulse
DIP 10 ON - Extra thrust when reached closing position to make sure
that the mechanical bolt is fixed into the ground
OFF - no impulse
JP1 => RESET
JP2 => Pay attention that the jumper is inserted!
JP3 => OPEN 1 motor (M1) - 1 leaf
CLOSE 2 motors (M1 and M2) - 2 leaves
JP4 => OPEN safety strip self-test DISABLED
CLOSE safety strip self-test ENABLED
PROG => SW1 Programming button
LOW SPEED => TM1 Electronic regulator for low speed in
approaching
Adjustment of low speed is carried out using the LOW SPEED Trimmer
that adjusts the output voltage to the
increase speed). Adjustment is carried out to set the correct speed at
the end of the opening and closing travel.
M1 => Regulator of MOTOR 1 current sensor sensitivity
M2 => Regulator of MOTOR 2 current sensor sensitivity
motor/s (turn clockwise to

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis