8

SPARE PARTS

The following spare parts are available for the product. Refer
to the exploded views on page 46:
- Fig. III for the FUA-1300/1800/2100;
- Fig. IV for the FUA-3000/4700.
Article number
Description
FUA-1300
0000100251
Motor plate FUA-1300/1800
0000100580
Fan wheel FUA-1300 (50-60Hz)
0000100585
Inlet flange FUA-1300/1800
0000100588
Outlet grid FUA-1300/1800/2100
0000100589
Motor 0,37 kW; 230-400V/3ph/50Hz
0000100590
Motor 0,37 kW; 230V/1ph/50Hz
0000100597
Inlet grid (fine) FUA-1300/1800/2100
0000101944
Connection flange with grid
FUA-1800
0000100251
Motor plate FUA-1300/1800
0000100581
Fan wheel FUA-1800 (50Hz)
0000100585
Inlet flange FUA-1300/1800
0000100588
Outlet grid FUA-1300/1800/2100
0000100591
Motor 0,55 kW; 230-400V/3ph/50Hz
0000100597
Inlet grid (fine) FUA-1300/1800/2100
0000101944
Connection flange with grid
FUA-2100
0000100252
Motor plate FUA-2100/2700
0000100582
Fan wheel FUA-2100 (50Hz)
0000100586
Inlet flange FUA-2100
0000100588
Outlet grid FUA-1300/1800/2100
0000100592
Motor 0,75 kW; 230-400V/3ph/50Hz
0000100593
Motor 0,75 kW; 115-230V/1ph/50-60Hz
0000100597
Inlet grid (fine) FUA-1300/1800/2100
0000101944
Connection flange with grid
FUA-3000
0000100253
Motor plate FUA-3000
0000100583
Fan wheel FUA-3000 (50Hz)
0000100594
Motor 1,1 kW; 230-400V/3ph/50Hz
FUA-4700
0000100584
Fan wheel FUA-4700 (50Hz)
0000101348
Motor 2,2 kW; 230-400V/3ph/50Hz
0000102528
Motor plate FUA-4700/TEV-585
9

ELECTRICAL DIAGRAM

Refer to the separately supplied electrical diagram.
10

DISPOSAL

After life of the product, dispose it of in accordance with
federal, state or local regulations.
0000100435/060614/A FUA-1300/1800/2100/3000/4700 (50Hz)

CE DECLARATION

CE declaration of conformity for machinery
We, Plymovent Manufacturing BV, Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the product(s):
- FUA-1800
- FUA-2100
- FUA-3000
- FUA-4700
which this declaration refers to, are in accordance with the
conditions of the following Directive:
- Machine Directive 2006/42 EC
- EMC directive 2004/108 EC
- LVD 2006/95/EC
- ErP directive 2009/125/EC
Alkmaar, the Netherlands, 6 June 2014
M.S.J. Ligthart
Product Manager
An installation is defined as a combination of several finished
products or components that are assembled by an installer at
a given place. The various parts of the installation are intended
to operate together in a particular environment and to perform
a specific task. The entire installation must comply with the
relevant directives and standards. The assembly instructions
given by the manufacturer, as well as the whole method of
installation, must be in accordance with good engineering
practices within the context of installations, as well as
installation rules. Considering the above, the installer will be
responsible for completing the installation and issuing the final
CE Declaration of Conformity.