Paul Hochköpper GmbH & Co. KG
Postfach 1727 • D-58467 Lüdenscheid • Tel.: +49 (0)2351 185-0 • Fax: +49 (0)2351 27666 • e-mail: peha@peha.de • Internet: www.peha.de
Installation and operating instructions
Easyclick receiver Plus with mounting plate
Art.no.: 451 FU-EP UP o.A.
1. General
1.1 Application
Various electric loads such as lamp bulbs, HV halogen
lamps, electronic ballast devices and inductive loads can
be switched with output 1 of the receiver. The Easyclick
receiver is operated manually with the touch button attach-
ment or with Easyclick transmitters (radio signal).
Before use, the transmitters must be assigned to the recei-
ver (max. 30 receivers). Every transmitter can control an
unlimited number of receivers.
Note: Read through the operating instructions carefully
before putting the device into service.
1.2 Warranty conditions
These operating instructions are an integral part of both the
device and our terms of warranty. They must be handed
over to the user. The technical design of the appliance is
subject to change without prior notification. PEHA products
are manufactured and quality-checked with the latest tech-
nology according to applicable national and international
regulations. Nevertheless, if a product should exhibit a de-
fect, PEHA warrants to make remedy as follows (regard-
less of any claims against the dealer to which the end-user
may be entitled as a result of the sales transaction):
In the event of a justified and properly-established claim,
PEHA shall exercise its prerogative to either repair or re-
place the defective device. Further claims or liability for
consequential damage are explicitly excluded. A justifiable
deficiency is one in which the device exhibits a structural,
manufacturing, or material defect that makes it unusable or
substantially impairs its utility at the time it is turned over to
the end-user. The warranty does not apply to natural wear,
unintended usage, incorrect connection, device tampering
or the effects of external influences. The warranty period is
for 24 months from the date of purchase by the end-user
from a dealer and ends not later than 36 months after the
device's date of manufacture. German law shall be applica-
ble for the settlement of warranty claims.
1.3 Disposal of the device
The device must be disposed of in compliance with the laws
and standards of the country in which it is operated!
2. Safety
CAUTION! Danger of electrical shock!
The housing contains current-carrying com-
ponents. Contact can lead to personal injury!
All work on the mains network and the de-
vice may only be done by an authorised
electrician.
• Disconnect power supply from the device prior to per-
forming any work on it.
• Secure the device against being powered on again.
• Check that the device is powered off.
• Close the housing securely before applying power.
The following must be observed:
• Prevailing statutes, standards and regulations.
• State-of-the-art technology at the time of installation.
• The device's operating instructions.
• Operating instructions can only cite general stipulations.
These are to be viewed in the context of a specific system.
This device is only intended to be used for its stated ap-
plication. Unauthorised conversions, modifications or
changes are not permissible! This device may not be used
in conjunction with other devices whose operation could
present a hazard to persons, animals or property.
451 FU-EP UP o.A. (Rev02_090220)
GB
3. Technical specifications
General data
Transmit frequency
Power supply
Power line
protection
Ambient temperature - 20 to + 40°C
Storage temperature - 40 to + 85°C
Test specifications
Identification
Protection type
Load types
Incandescent lamps
HV-halogen lamps
Inductive
Electronic ballast
Range in buildings
Masonry
Reinforced concrete
Plasterboard/wood
Note: The strength of the radio signal between sender and
receiver decreases with increasing distance. The visually
unobstructed range is about 30 m in passageways and
100 m in open rooms. The range can be increased through
the use of an Easyclick repeater.
4. Installation and commissioning
4.1 Safety information
Installation and commissioning may only be done by an
authorised electrician. Mains power (230 V ~/50 Hz) to elec-
trical equipment must be switched off during installation.
Applicable laws and standards of the country in which the
device is operated must be observed!
4.2 Installation information
• CAUTION! Remove or insert the attachment only,
if the power supply is switched off !
• NEVER install Easyclick receivers in a metal enclosure
or in the immediate vicinity of large metal objects.
• Installation close to floor level or on the floor is
not recommended.
4.3 Installation
This device is intended for installation in a flush-mount, 60
mm Ø installation box. The receivers are to be equipped with
the 1-5 multipurpose frame from the PEHA switch range.
451 FU-EP UP o.A.
1
µ
L max.2500W
230V~/50Hz
N N L L 1
N N L L 1$
230V/50Hz~
F
L
N
• Install flush-mounted installation box in a suitable
position or remove existing switch.
• Protect power supply line with an automatic circuit
breaker (F = max. 16 A)!
• Install connection cables.
• Insert the device into the flush-mount installation box
and screw-fasten it securely in place.
• Place frame on mounting plate and carefully insert
touchbutton attachment into plug-in socket.
D a t u m
N a m e
126363-01
Bearb.
G e p r.
868,3 MHz
230V~ / 50 Hz
Circuit breaker rated
for 16 A, maximum
EN 60669-2-1
CE ; KEMA/KEUR
IP20
2500 W
1200 W
600 VA
3 units
20m, through 3 walls max.
10m, through 1 wall/ceiling max.
30m, through 5 walls max.
Mounting plate
Plug-in socket
for attachment
CLR / MODE
button with LED
CLR/MODE
Delete all transmitters
and parameter setting
LRN/SET
LRN / SET
button with LED
Learn mode and func-
tion programming
Connection
terminals
Learn mode:
LED = red
Function programming:
LED = green or orange
1-Kanal UP Schaltempfänger
mit Ast
4.4 Commissioning
On delivery, the receiver with touch button attachment is
immediately ready for operation. It is not necessary to as-
sign the attachment to the receiver. Function 1 of the recei-
ver is preset for the attachment.
• Switch on power supply after installation.
• Program the receiver (see Point 6).
5. Operation
The Easyclick receiver is operated manually with the touch
button attachment or with Easyclick transmitters (radio si-
gnal). Before use, the transmitters must be assigned to the
receiver (max. 30 receivers). The receiver's Function 1 is
preset after assigning a transmitter to the receiver. Every
transmitter can control an unlimited number of receivers.
The function of the receiver for the attachment or an Easy-
click transmitter can be changed in function programming.
6. Programming
CAUTION! Remove or insert the attachment only, if
the power supply is switched off !
• Switch off the power supply and remove the attachment.
• Switch on the power supply for programming.
• Switch off the power supply after programming and
connect the attachment to receptacle.
6.1 Learn mode (assigning or deleting transmitters)
LRN/SET button
press briefly
Activate transmitter once
Learn mode
(e.g. press button)
(LED blinks red)
Transmitter assigned
LRN/SET button
Receiver = Function 1
press briefly
Idle state
Transmitter deleted
(LED off)
Notes:
– No transmitter is assigned to the receiver
in its delivered state.
– Several transmitters can be assigned (max. 30 receivers)
or deleted in learn mode.
– A transmitter is alternately assigned (LED on) or deleted
(LED off) each time the button is pressed!
– The receiver's Function 1 is preset after assigning a
transmitter to the receiver. The function can be changed
for every transmitter (see point 6.3).
– If no action takes place, learn mode will be terminated
after 30 s.
6.2 Deleting all assigned transmitters
CLR/MODE button long activation
All transmitters deleted
Learn mode (LED blinks red)
LRN/SET button press briefly
Idle state (LED off)
(LED 1 on)
(LED off)
s. Point 6.1
GB - 1