1.3. ELECTROLYSIS CELL SPECIFICATIONS

Recommended salinity:
Electrodes :
Max. recommended pressure:
Temperatu r e :
M a t e r i a l :
Pipe conne c t io n s :
Production
(at 25ºC and 6 g/l salinity)
Minimum flow
Electrode number:

2. - INSTALLATION INSTRUCTIONS

2.1. POWER SUPPLY

Always install the POWER SUPPLY of the IDEGIS system vertically on a solid
and rigid surface (wall) as shown in the diagram of recommended installation. In
order to guarantee a good state of conservation, it is also strongly
recommended to install the equipment in a well ventilated dry place.
Due to the IP degree of the POWER SUPPLY of the IDEGIS system, outdoor
installation is not allowed. The POWER SUPPLY must be preferably installed a
bit distant from the electrolysis cell so that it cannot accidentally suffer water
splashes.
Beware of corrosive atmosphere formation due to pH-decreasing solutions
(specially, those ones based on hydrochloric acid "HCl", also commercially
denominated "muriatic acid" or "salfumant"). Power supply must be connected
in the electrical control box of the pool, so that the pump and the IDEGIS system
are turned on simultaneously.
4-6 g/l (4000 – 6000 ppm)
Titanium with SELF-CLEANING coating
2
1 Kg/cm
less than 40ºC
methacrylate-based polymer
gluing with PVC adhesive Ø 63 mm
D-10
10 g./h.
3
2 m
/h
4
additional flow
additional flow
detector
D-18
18 g./h.
25 g./h.
3
4 m
/h
5 m
6
additional flow
detector
detector
D-25
3
/h
8
2